Parameter
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
139
4
P2060
This parameter determines the start-up display page after power is applied to the drive.
P2061
This parameter determines the content of the multi function display.
P2060
Start Anzeige
0 to 4
EE
Start-up display selection
0
ON
BM_u_StartUpDisplaySelection
1:1
Value
Meaning
0
Display the frequency command value (Fxxx)
1
Display the actual output frequency (Hxxx)
2
Display the output current in A supplied to the motor (Axxx)
3
Display the content of user-defined unit (Uxxx)
4
FWD/REV command
P2061
Inhalt Multi-Funktions-Anzeige
0 to 14
EE
Content of multi function display
0
ON
BM_u_MultiFunctionDisplay
1:1
Value
Meaning
0
Display the content of user-defined unit (Uxxx)
1
Display the counter value which counts the number of pulses on TRG
terminal
2
reserved
3
Display the actual DC bus voltage in V
DC
of the b maXX
®
1000
4
Display the output voltage in V
AC
of terminals 1U2, 1V2, 1W2 to the
motor