4
P0850
The operation mode
must be set to 249 using auto tuning.
Start Auto Tuning by pressing RUN key after this parameter is set to 1 or 2.
When set to 1, it will only auto detect R1 value and
must be input manually.
When set to 2, the b maXX
®
1000 should be unloaded and the values of
and
will be set automatically.
The steps for AUTO-Tuning are:
1
Make sure that all the parameters are set to factory settings and the motor wiring is
correct.
2
Make sure the motor has no-load before executing auto-tuning and the shaft is not con-
nected to any belt or gear motor.
3
Fill in
values.
4
is set to 2, the b maXX
®
1000 will execute
auto-tuning immediately after receiving a „RUN“ command. (Note: The motor will run!).
The total auto tune time will be 15 s
drives need longer accel/decel time (factory setting is recommended). After executing
Auto-tune,
is set to 0.
5
After executing, please check if there are values filled in
and
. If
not, please press RUN key after setting
again.
6
Then you can set
to 1 (vector control) and set other parameters according
to your application requirement.
P0850
Selbstoptimierung Motorparameter
0 to 2
EE
Motor auto parameters auto tuning
0
STOP
BM_u_MotorAutoParaAutoTuning
1:1
-
Value
Meaning
0
Disable
1
Auto tuning R1 (motor doesn’t run)
2
Auto tuning R1 and no load test (with running motor)
NOTE
1
In vector control mode it is not recommended to have motors run in parallel.
2
It is not recommended to use vector control mode if motor rated power exceeds the rated
power of the b maXX
®
1000.