Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
14
5 OPERATION ENABLED
SWITCHED ON
n
Event:
m
Command ’inhibit operation’ or
m
Pulse enable input MI6 = Low
n
Condition:
m
Zero speed is reached or for „inhibit operation“ an immediate pulse inhibit has
been set
n
Action:
m
Drive inhibit is commenced (according to settings: braking or coasting to a
standstill)
6 SWITCHED ON
READY-TO-START
n
Event:
m
Command ’shut down’ or
m
Pulse enable input MI6 = Low
n
Action:
m
Feed unit ’ready for use’-signal monitoring will be deactivated
7 READY-TO-START
INHIBIT READY TO START
n
Event:
m
Command ’quickstop’ or
m
Command ’inhibit voltage’ or
m
Quickstop input = Low (default quickstop input MI5 = 23)
n
Action:
m
none
8 ENABLE OPERATION
SHUT DOWN DRIVE ACTIVE
n
Event:
m
Command ’Shut down’
n
Action:
m
Shut down of drive is commenced (according to settings: braking or coasting
to a standstill)
9 OPERATION ENABLED
SWITCH-ON INHIBIT
n
Event:
m
Command ’inhibit voltage’
n
Action:
m
Drive operation is inhibited
10 SWITCH ON
INHIBIT READY TO START
n
Event:
m
Command ’inhibit voltage’ or
m
Command ’quickstop’ or
m
Quickstop input = Low (default quickstop input MI5 = 23)
n
Action:
m
none