4.3
P2031
To set a password to protect your parameter settings.
If the display shows 0, no password is set or password has been correctly entered in
. All parameters can then be changed, including
The first time you can set a password directly. After successful setting of password the
display will show 1.
Be sure to record the password for later use.
To cancel the parameter lock, set the parameter to 0 after inputting correct password into
The password consists of min. 1 digits and max. 4 digits.
How to make the password valid again after decoding by
Method 1: Re-input original password into
(or you can enter a new password if
you want to use a changed or new one).
Method 2: After rebooting, password function will be recovered.
Figure 63:
Password protect set
P2031
Passwortschutz
0 to 9999
EE
Password protect set
0
STOP
BM_u_PasswordProtectSet
1:1
-
Value
Meaning
0
Display: No password set or successful input in
1
Display: Password has been set
0 to 9999