Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
134
4.3
P1372
This parameter sets one of the skip frequencies. For further information see
P1373
This parameter sets one of the skip frequencies. For further information see
P1374
This parameter sets one of the skip frequencies. For further information see
P1375
This parameter sets one of the skip frequencies. It will cause the b maXX
®
1000 never to
remain within these frequency ranges with continuous frequency output.
These six parameters should be set as follows
≥
≥
≥
≥
≥
.
The frequency ranges may be overlapping.
Figure 61:
Skip frequencies
P1372
Ausblendfrequenz 2 obere Grenze
0.00 to 600.00 Hz
EE
Skip frequency 2 upper bound
0.00
STOP
BM_u_SkipFrequency2UpperBound
100:1
-
P1373
Ausblendfrequenz 2 untere Grenze
0.00 to 600.00 Hz
EE
Skip frequency 2 lower bound
0.00
STOP
BM_u_SkipFrequency2LowerBound
100:1
-
P1374
Ausblendfrequenz 3 obere Grenze
0.00 to 600.00 Hz
EE
Skip frequency 3 upper bound
0.00
STOP
BM_u_SkipFrequency3UpperBound
100:1
-
P1375
Ausblendfrequenz 4 untere Grenze
0.00 to 600.00 Hz
EE
Skip frequency 4 lower bound
0.00
STOP
BM_u_SkipFrequency4LowerBound
100:1
-