Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
92
4.3
P1120
If this parameter is set to 1 and the desired value of counter is attained, the AC drive will
treat it as a fault. The drive will stop and show the error code 051C
hex
, „EF“ message on
the display.
P1121
This parameter is used to set control of mechanical brake via the output terminals (relay
or MO1) when
is set to 21. Refer to the following example for de-
tails.
Example:
1. Case 1:
≥
2. Case 2:
≤
Figure 40:
Brake release frequency
P1120
EF, wenn Eingang Zählerwert erreicht
0 to 1
EE
EF active when terminal count value attained
0
STOP
BM_u_EFActiveCountValueAttained
1:1
Value
Meaning
0
Continue operation
1
Stop immediately and display (EF), error code 051C
hex
P1121
Frequenz Bremse lösen
0.00 to 20.00 Hz
EE
Brake release frequency
0.00 Hz
STOP
BM_u_BrakeReleaseFrequency
100:1