Parameter
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
45
4
P0802
The factory setting for source or first operation command is 2.
When the b maXX
®
1000 is controlled by an external terminal, please refer to
/
for details.
* digital keypad is optional
P0802
Quelle des ersten Betriebskommandos
1 to 5
EE
Source of first operation command
5
STOP
BM_u_SourceFirstOperComm
1:1
-
Value
Meaning
0
by digital keypad *
1
by external terminals, keypad STOP enabled *
2
by external terminals, keypad STOP disabled *
3
by ProDrive communication interface, keypad STOP enabled *
4
by ProDrive communication interface, keypad STOP disabled *
5
by CANopen
NOTE
Value 0, 1 and 2 needs the digital input PULSE ENABLE (input MI6).
Value 3, 4 and 5 needs the digital input PULSE ENABLE (input MI6) and QUICKSTOP (de-
fault multi function input MI5).