Parameter
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
23
4
P0010
Display of power unit rate current.
P0024
This parameter determines the operation mode of the cooling fan.
P0032
This parameter determines the base voltage for 50 Hz power supply.
P0033
This parameter determines the b maXX
®
1000 maximum output frequency. All the drive
command sources (analog inputs 0 to +10 V and 4 to 20 mA) are scaled to correspond to
this output frequency range.
P0010
Leistungsteil Nennstrom
0.0 to 99.9 A
-
Power unit rate current
0.0 A
A
BM_u_AmpNomCurrent
10:1
-
P0024
Lüfterregelung
0 to 3
EE
Fan control
0
ON
BM_u_FanControl
1:1
-
Value
Meaning
0
Always fan on
1
Fan off after 1 min drive stop
2
Fan on when drive run
Fan off when drive stop
3
Fan on when preliminary temperature attained
P0032
50 Hz Spannungsauswahl
0 to 1
EE
50 Hz base volt selection
0
STOP
BM_u_BaseVoltSelect
1:1
-
Value
Meaning
0
230V / 400V
1
220V / 380V
P0033
Maximale Ausgangsfrequenz
50.00 to 600.00 Hz
EE
Maximum output frequency
50.00 Hz
STOP
BM_u_MaxOutputFreq
100:1
-