Parameter
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
87
4
When extension card is installed, the number of the multi function input terminals will in-
crease according to the extension card. The maximum number of the multi-function input
terminals is 12.
Figure 35:
Display status external multi function input
P1106
The multi-function input terminals are falling-edge triggered. For standard b maXX
®
1000
(without extension card), there are MI1 to MI6 and
no action.
Figure 36:
Display status multi function input terminal 1
P1106
Statusanzeige Multi-Funktions-Eingänge
0 to 4095
-
Display the status of multi function input termi-
nals
0
A
BM_u_StatusMulitFunctionInputTerminals
1:1