Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
96
4.3
P1126
The parameter are used to set the analog input reference values and is based on percent-
age of
). For further information see
P1127
Please note the ACI/AVI switch on the b maXX
®
1000.
For further information see
and
P1128
The parameter are used to set the analog input reference values and is based on percent-
age of
). For further information see
P1129
Please note the ACI/AVI2 switch on the b maXX
®
1000. Switch to ACI for 4 to 20 mA an-
alog current signal (ACI) (
should be set to 0) and AVI2 for analog voltage signal
(AVI2) ((
should be set to 1).
Figure 46:
ACI/AVI2 selection
This parameter selects between ACI and AVI2.
P1126
Minimale AVI Frequenz
0.0 to 100.0 %
EE
Minimum AVI frequency
0.0 %
STOP
BM_u_MinimumAVIFrequency
10:1
P1127
Maximale AVI Spannung
0.0 to 10.0 V
EE
Maximum AVI voltage
0.1 V
STOP
BM_u_MaximumAVIVoltage
10:1
P1128
Maximale AVI Frequenz
0.0 to 100.0 %
EE
Maximum AVI frequency
0.0 %
STOP
BM_u_MaximumAVIFrequency
10:1
P1129
ACI/AVI2 Auswahl
0 to 65535
EE
ACI/AVI2 selection
0
STOP
BM_u_ACIAVI2Selection
1:1
Value
Meaning
0
ACI
1
AVI2