Power I/O Connections
Pin #
Wire Color
Description
Direction
2
Brown
10-30V dc
Input
7
Blue
Common (Signal Ground)
Input
6
Pink
External Trigger
Input
5
Gray
Remote Teach
Input
1
White
Output 1
Output
8
Red
Ready
Output
4
Yellow
Strobe Out (5V dc only)
Output
3
Green
Output 2
Output
9
Orange
Output 3
Output
10
Light Blue
RS-232 TX
Output
11
Black
RS-232 Signal Ground
Output
12
Violet
RS-232 Rx
Input
iVu Trigger, Remote Teach, and I/O Waveforms
The iVu has two input signals—Trigger and Remote Teach. The default setting is to detect the Trigger or Remote Teach input on the low
to high transition. This setting can be changed in the Main Menu > System > Discrete I/O > Input Polarity screen on the sensor.
iVu Low-to-High Trigger and Remote Teach Input Waveforms
The iVu Trigger and Remote Teach input waveforms are shown below.
Power up
Trigger
Remote
Teach
Pink
Wire Color
Function
Gray
The sensor triggers from low to high, and Remote Teach behaves electrically like trigger (see above).
iVu High-to-Low Trigger and Remote Teach Input Waveforms
The iVu High-to-Low Trigger and Remote Teach input waveforms are shown below.
Trigger
Remote
Teach
Pink
Wire Color
Function
Gray
Power up
iVu Plus BCR User's Manual
12
www.bannerengineering.com - tel: 763-544-3164
Rev. B
Summary of Contents for iVu Plus BCR
Page 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Page 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Page 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Page 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...