Installing Filters on the iVu Series Sensor
NOTE: Failure to follow these instructions can cause damage to your iVu Series sensor.
To install a filter on the iVu Series sensor with Micro Lens, use the illustration as a guide and follow the steps listed below.
A
Lens
B
Focusing Window
C
Locking Clip
D
Locking Screw
E
Filter Cap
F
Filter
1. Use the 1/16" hex key to remove the Focusing Window locking screw (D).
NOTE: The Locking Clip (C) inserts in a groove near the top of the Focusing Window (B). When remov-
ing the window, the Locking Clip will be loose. Be careful not to lose the clip while removing the window.
2. Unscrew the Focusing Window by turning it clockwise approximately 5 complete turns or until the Focusing Window disengages
from the light/lens assembly.
NOTE: The light/lens assembly may include an integrated ring light or a blank disk if an integrated ring
light is not used. Be careful that the light/lens assembly does not pull out when removing the Focusing
Window. Give a slight tug on the Focusing Window when you think you've unscrewed it far enough. If
the lens assembly moves with the window, continue to rotate the window clockwise until the lens assem-
bly does not move.
3. Set the Focusing Window aside. Be careful not to get any debris on the window's O-ring.
4. If present, remove the protective covering on the filter.
5. Place the filter into the Filter Cap and press the cap onto the lens.
6. Once the filter is installed, place the Focusing Window back into the housing while inserting the Locking Clip into the groove as
shown below.
iVu Plus BCR User's Manual
Rev. B
www.bannerengineering.com - tel: 763-544-3164
15
Summary of Contents for iVu Plus BCR
Page 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Page 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Page 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Page 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...