9.5.1 Holding Registers
The Holding registers are used by the PLC to push values to the iVu Plus sensor. These values are accessed in the register address
range of 40001 - 40240. To write, use Function Codes 6/16 (Preset Single/Multiple Registers). Also available in this range of registers are
the registers containing output data. These outputs are available using the address range of 41001 - 41480. To read these output into the
PLC use Function Code 03 (Read Holding Registers).
Input Registers Map
REGISTER
WORD NAME
DATA TYPE
40001
Output Coil Bits
16-bit integer
40002-3
Product Change Number
32-bit integer
40004-50
reserved
32-bit integer
40051
Command
16-bit integer
40052
Command Parameter Int16
16-bit integer
40053-54
Command Parameter Int 32
32-bit integer
40055-56
Command Parameter
Float
40057-58
Command Parameter String Length
32-bit integer
40059-108
Command Parameter String
100 Byte Array
40109
reserved
16-bit integer
40110-111
BCR String/Mask Length
32-bit integer
40112-211
BCR String/Mask
200 Byte Array
40212-240
reserved
iVu Plus BCR User's Manual
Rev. B
www.bannerengineering.com - tel: 763-544-3164
125