During the Data and Image export operation the sensor's output channels might become full. This can occur if the sensor is
producing export data (frames) faster than the data can be exported from the device (due to bandwidth limitations) or faster
than the client is reading the channel export data.
This setting affects how the sensor will behave in this situation.
• Select Hold READY to ensure that all frames are transmitted. In this case, the READY signal will remain inactive (sensor
is busy) until the new frame has been added to the channel for transmission. Triggers might be missed during this time.
• Select Do not hold READY to cause the sensor to discard the new frame if the channel is full and thus activate the
READY signal immediately after the current inspection is complete. In this case, the discarded frames will not be trans-
mitted.
Communications Channel Ports
The following are the default Ethernet port settings for the communications channels:
• Command Channel — 32200
• Data Export — 32100
• Image Export — 32000
6.2.2 Setting Up Serial Communications
The general flow for setting up for serial communications:
1. Prepare the connection — RS-232 wiring.
Electrically connect the control device and the iVu sensor. On the iVu, the pins/wire colors used for serial communications via
RS-232 are shown in the table below.
iVu RS-232 Connections
Pin #
Wire Color
Description
10
Light-Blue
TX
11
Black
Signal Ground
12
Violet
RX
2. Configure port settings (baud rate, data bits, parity, and stop bits) on the iVu to match the settings on the control device. Go to
Main Menu > System > Communications > Serial I/O .
iVu Plus BCR User's Manual
74
www.bannerengineering.com - tel: 763-544-3164
Rev. B
Summary of Contents for iVu Plus BCR
Page 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Page 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Page 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Page 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...