Command
Group
Item
Description
Get
Info
RemoteModelNumber
The model number of the re-
mote display as a string.
Get
Info
RemoteSerialNumber
The serial number of the remote
display as a string.
Examples
>>
get info companyname
\x0D\x0A
<<
OK\x0D\x0A
<<
"Banner Engineering Corp."\x0D\x0A
>>
get info bootnumber
\x0D\x0A
<<
OK\x0D\x0A
<<
42\x0D\x0A
>>
get info uptimer
\x0D\x0A
<<
OK\x0D\x0A
<<
4:42:42:324\x0D\x0A
8.4 System Command Group
Command
Group
Item
Description
Do
System
Reboot
Reboots the sensor. Pre-empts other
commands except Save.
Do
System
Save
Saves inspection and configuration pa-
rameters. Blocks until finished. Should
be used sparingly.
Get
Ethernet
IPAddress
Get the current active IP address of
the sensor as a string.
Get
Ethernet
SubnetMask
Get the current active subnet mask of
the sensor as a string.
Get
Ethernet
Gateway
Get the current active Gateway ad-
dress of the sensor as a string.
Set
Ethernet
IPAddress
Set IP address of the sensor. A valid
IP address must be supplied as a
string (for example: 192.168.0.1). A
'Reboot' command from the command
channel must follow in order to make
the new IP address effective. You may
also set new Subnet Mask and Gate-
way address as required before a 'Re-
boot' command is sent to the sensor.
Set
Ethernet
SubnetMask
Set new subnet mask. A 'Reboot' com-
mand is required to be sent from the
command channel in order to make
the new mask effective.
iVu Plus BCR User's Manual
88
www.bannerengineering.com - tel: 763-544-3164
Rev. B
Summary of Contents for iVu Plus BCR
Page 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Page 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Page 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Page 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...