2.2.6 Remote Teach
The Remote Teach function is a method of remotely updating compare data while the iVu sensor is running. The sequence of events for
executing a Remote Teach as follows:
1. With the sensor Ready, pulse the Remote Teach line.
2. The sensor recognizes that the Remote Teach line has been pulsed and waits for the next valid trigger.
3. At the next valid trigger, Ready goes inactive (the Green Ready LED shuts OFF), and the sensor acquires a new image.
When a Remote Teach occurs, the data of the first read barcode is saved as Data Compare input. Inspections executed on the next
trigger will use the new data for comparison with subsequently read barcodes. If the previous input data contained any masked charac-
ters, Remote Teach will retain the masked characters only if the new data is of the same length as the previous input data. If the length
does not match, masking is removed.
2.3 iVu Plus BCR Emulator
The iVu Plus BCR Emulator is a Windows application that allows you to operate in a Windows environment exactly as you would on the
iVu Series sensor itself. In general, the Emulator is an inspection debugging tool where you can:
1. Import stored inspections and configuration from an iVu Plus BCR sensor.
2. Modify inspection parameters on the emulator.
3. Restore the updated configuration back to the sensor.
iVu Plus BCR User's Manual
20
www.bannerengineering.com - tel: 763-544-3164
Rev. B
Summary of Contents for iVu Plus BCR
Page 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Page 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Page 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Page 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...