The iVu Plus BCR RS232 port or ethernet port can be used to output barcode data to other applications. To access the Data Export
screen, go to Main Menu > System > Communications > Data Export . The user can enable or disable this feature. When enabled:
• if the sensor is configured for either External-Single or External-Gated trigger modes, every trigger results in the transmission of out-
put data (if the sensor does not successfully read a barcode, the output will be NO_READ).
• if the sensor is configured for Continuous trigger mode, the sensor will only transmit output barcode data upon a successful read.
To access the Serial Output screen, go to Main Menu > System > Communications > Serial I/O
When RS-232 serial output is enabled, the user can configure:
• Serial Port Settings (listed below)
• Type of Data to Export (listed below)
• Output Format (listed below)
To access the Ethernet Output screen, go to Main Menu > System > Communications > Ethernet I/O .
When ethernet output is enabled, the user can configure:
• IP Address, Port number, Subnet Mask, and Gateway
• Type of Data to Export (listed below)
• Output Format (listed below)
Type of Data to Export:
• Pass/Fail Output
• Inspection Name
• Barcode Count
• Data Length
• Symbol Type
• Barcode Data
• Frame Number
• Inspection Time (ms)
Serial Port Settings:
• Baud Rates
• Start Bits
• Stop Bits
• Data Bits
• Parity Control
Output Format:
• Start String
• Delimiter
• End String
iVu Plus BCR User's Manual
Rev. B
www.bannerengineering.com - tel: 763-544-3164
19
Summary of Contents for iVu Plus BCR
Page 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Page 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Page 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Page 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...