Inputs to the PLC
iVu_Input1 0x64 (100) - 30 Registers
WORD #
WORD NAME
DATA TYPE
0
Input Bits ACK Register
16-bit integer
1
Output Bits Register
16-bit integer
2-3
Error Code
32-bit integer
4-5
Inspection Number
32-bit integer
6-7
Iteration Count
32-bit integer
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current Inspection Time
Float
16-29
reserved
iVu_Input2 0x65 (101) - 240 Registers
Sensor Type - Area (iVu Plus TG)
WORD #
WORD NAME
DATA TYPE
0
Input Bits ACK Register
16-bit integer
1
Output Bits Register
16-bit integer
2-3
Error Code
32-bit integer
4-5
Inspection Number
32-bit integer
6-7
Iteration Count
32-bit integer
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current Inspection Time
Float
16-29
reserved
30-52
Inspection Name
2-Word
40-unicode chars
53-54
Frame Number
32-bit integer
WORD #
WORD NAME
DATA TYPE
55
Sensor Type ID
16-bit integer
56-57
Area Count
32-bit integer
58-59
Area Range Min
32-bit integer
60-61
Area Range Max
32-bit integer
62-170
reserved
171
Command Status
16-bit integer
172
Command Response Int16
16-bit integer
173-174
Command Response Int32
32-bit integer
175-176
Comand Response Float
Float
177-178
Command Response
Length
32-bit integer
179-228
Command Response Data
100 Byte Array
229-239
reserved
iVu Plus BCR User's Manual
Rev. B
www.bannerengineering.com - tel: 763-544-3164
113
Summary of Contents for iVu Plus BCR
Page 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Page 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Page 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Page 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...