9.7 Error Codes
The iVuPlus sensor provides error codes in cases when commands failed to execute successfully. If such an error occurs, the Execution
Error flag is set in the Output Bit/Coil Register. When this bit is set, read the Error Code register to know the reason of failure. Below is
the list of error codes:
Numeric ID
Text ID
Description
0
SUCCESS
Command processed successfully.
500
IE_TRIGGER_MODE_EXPECTED
The Trigger Mode must be set to 'Industrial Ethernet' to per-
form this operation.
510
IE_COMMAND_NOT_FOUND
The numeric Command ID specified was not found.
520
IE_COIL_ACTION_FAILED
The coil action resulted in a failure.
521
IE_COIL_ALREADY_BUSY
The coil was asserted before previous execution completed.
522
IE_COIL_NOT_FINISHED
The coil was de-asserted prior to execution completing.
523
IE_COIL_ANOTHER_ACTION_PENDING
The coil was asserted prior to another coil execution com-
pleting.
524
IE_COIL_MULTIPLES_DETECTED
Multiple coils were asserted simultaneously.
525
IE_COIL_ACK_INHIBITED
The coil action's output ACK was inhibited because the in-
put coil was no longer set.
10252
COMMAND_NOT_FINISHED
Attempt to issue command when a previous command has
not finished
10340
MINIMUM_VALUE_EXCEEDED
New item value is below the minimum
10341
MAXIMUM_VALUE_EXCEEDED
New items value is above the maximum
10900
SENSOR_NOT_READY
Command specified requires sensor to be in the READY
state.
10920
SENSOR_TYPE_NOT_ACTIVE
Command refers to a inactive sensor type.
10950
DEVICE_TYPE_INVALID
Command not supported on this device type.
15100
STRING_TOO_LONG
String value specified exceeds maximum allowable length
20002
COMPARE_DATA_DISABLED
Operation requires Barcode compare to be enabled
20003
COMPARE_MASK_INVALID
Compare mask invalid. Expecting string of 1's and 0's with
length equal to compare data string
20004
NUMBER_TO_FIND_NOT_ONE
Barcode number to find must be set to one for this opera-
tion.
20005
COMPARE_MASK_DISABLED
Operation requires Barcode compare mask to be enabled.
80300
TEACH_SENSOR_TYPE_INVALID
Teach requires Match Sensor type.
80401
PRODUCT_CHANGE_INVALID_INSPECTION
Attempt to product change to a unknown or invalid inspec-
tion.
80402
PRODUCT_CHANGE_TIMEOUT
The Product Change operation timed out.
9.8 Diagnostic Guide
iVu Plus BCR User's Manual
140
www.bannerengineering.com - tel: 763-544-3164
Rev. B
Summary of Contents for iVu Plus BCR
Page 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Page 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Page 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Page 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...