Image Export Channel
Main Menu > System > Communications > Image Export
When the Image Export Channel is enabled, the sensor will transmit the acquired image on every trigger. The image is transmitted as a
bitmap (BMP) file. This operation is only available over Ethernet I/O.
3.2.6 Discrete I/O
The Discrete I/O options are used to adjust iVu input and output settings.
Main Menu > System > Discrete I/O
Input Polarity
The iVu has two input signals—Trigger and Remote Teach. The operation of these signals is dependent on the Input Polarity setting.
• Low To High - The Trigger and Remote Teach are detected on a low to high transition of the signal.
• High To Low - The Trigger and Remote Teach are detected on a high to low transition of the signal.
The default setting for a PNP sensor is Low To High, and for an NPN sensor it is High To Low. The user can change the setting on the
Input Polarity screen.
Main Menu > System > Discrete I/O > Input Polarity