9.6.3 Input Registers
The Output registers are used to push output values from the iVu Plus to the PLC. MSG (message) commands used to Read (N7) and
Write (N14) to the sensor.
Input Registers Map (N7)
Sensor Type - Area (iVu Plus TG)
WORD #
WORD NAME
DATA TYPE
0
Coil ACK Bits
16-bit integer
1
Output Coil Bits
16-bit integer
2-3
Error Code
32-bit integer
4-5
Inspection Number
32-bit integer
6-7
Iteration Count
32-bit integer
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current Inspection Time
Float
16-29
reserved
30-52
Inspection Name
2-Word
40-unicode chars
53-54
Frame Number
32-bit integer
WORD #
WORD NAME
DATA TYPE
55
Sensor Type ID
16-bit integer
56-57
Area Count
32-bit integer
58-59
Area Range Min
32-bit integer
60-61
Area Range Max
32-bit integer
62-170
reserved
171
Command Status
32-bit integer
172
Command Response Int16
16-bit integer
173-174
Command Response Int32
32-bit integer
175-176
Comand Response
Float
177-178
Command Response Length
32-bit integer
179-228
Command Response Data
100 Byte Array
229-239
reserved
iVu Plus BCR User's Manual
Rev. B
www.bannerengineering.com - tel: 763-544-3164
135
Summary of Contents for iVu Plus BCR
Page 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Page 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Page 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Page 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...