www.baldormotion.com
3-42 Basic Installation
MN1943
3.9.6 Resistor pulse load rating
The regeneration resistors shown in Table 6 can dissipate power levels greater than the stated
continuous power rating, provided the duty cycle (see section 3.9.7) is reduced, as shown in
Figure 24.
0.08
0.17
0.25
0.33
0.42
0.5
Duty cycle
Po
w
er
(W)
0
3000
6000
9000
12000
15000
21000
18000
24000
1
2
3
1
100 W models: Maximum pulse 5 kW for 1 s, 120 s off.
2
300 W models: Maximum pulse 15 kW for 1 s, 120 s off.
3
500 W models: Maximum pulse 25 kW for 1 s, 120 s off.
10:120
20:120
30:120
40:120
50:120
60:120
on:off (s)
absolute
27000
Figure 24 - Regeneration resistor pulse load rating