www.baldormotion.com
Basic Installation 3-15
MN1943
3.4.2 AC input and regeneration resistor output wiring
The installation methods shown in Figure 7 will improve the reliability of the system, reduce
troubleshooting time, and optimize the EMC (electromagnetic compatibility) behavior of the
control system. The MotiFlex
e
100’s protective earth connection does not provide
electromagnetic compatibility. Its purpose is to prevent exposed metalwork becoming live in the
case of a serious failure. To avoid EMC coupled effects within the panel design:
1. Do not run AC filter input and output power cables in close proximity.
2. Do not run motor output power cables with any other cables, especially Ethernet, signal
cables, or ’clean’ AC power.
3. Do not run power and signal cables in the same trunking. If the cables must run in parallel,
they should be separated by 200 mm (8 in) or placed in separate metal trunking.
4. If any of the above cables must cross, they must do so at 90 degrees to minimize coupling.
5. Ensure all sources of electrical noise are suppressed, e.g. solenoids, relays, contactors.
AC power
from fuses
and reactor
Mount AC filter and
MotiFlex
e
100 on the
same metal panel.
Regeneration resistor.
For long cables, use
shielding as shown for AC
power cables.
DO NOT TOUCH!
Regeneration resistors can
become extremely hot!
Locate away from vulnerable
components and wiring
Connect AC power cable shield to
metal panel, using conductive shield
earth/ground clamps.
Drive
earth
must
be
at least
10 mm
2
(7 AWG)
OPT-CM-001
AC power wires
should be as short as
possible, typically
less than 0.3 m (1 ft).
Longer wires must
be shielded as
shown.
Wire colors
may vary
according
to region.
CAUTION
Figure 7 - Panel layout best practice
Summary of Contents for MotiFlex e100
Page 1: ......
Page 2: ......
Page 60: ...www baldormotion com 3 44 Basic Installation MN1943 ...
Page 102: ...www baldormotion com 5 28 Input Output MN1943 ...
Page 136: ...www baldormotion com 7 8 Troubleshooting MN1943 ...
Page 172: ...www baldormotion com 8 36 Specifications MN1943 ...
Page 188: ...www baldormotion com B 6 Control System MN1943 ...
Page 204: ...www baldormotion com C 16 Mint Keyword Summary MN1943 ...
Page 216: ...Index MN1943 ...
Page 218: ...www baldormotion com Comments MN1943 Thank you for taking the time to help us ...
Page 219: ......
Page 220: ......