www.baldormotion.com
Specifications 8-31
MN1943
8.6 Input / output
8.6.1 Analog input - AIN0 (X3)
Unit
All models
Type
Differential
Common mode voltage range
VDC
±10
Input impedance
k
Ω
120
Input ADC resolution
bits
12 (includes sign bit)
Equivalent resolution
(±10 V input)
mV
±4.9
Sampling interval
μ
s
250
8.6.2 Digital inputs - drive enable and DIN0 general purpose (X3)
Unit
All models
Type
Opto-isolated inputs
Input voltage
Nominal
Minimum
Maximum
Active
Inactive
VDC
24
12
30
> 12
< 2
Input current
(maximum, per input)
mA
50
Sampling interval
ms
1
Minimum pulse width
μ
s
5
8.6.3 Digital inputs DIN1, DIN2 - high speed general purpose (X3)
Unit
All models
Type
Opto-isolated inputs
Input voltage
Nominal
Minimum
Maximum
Active
Inactive
VDC
24
12
30
> 12
< 2
Input current
(maximum, per input)
mA
20
Maximum input frequency
MHz
1
Minimum pulse width
ns
250
Summary of Contents for MotiFlex e100
Page 1: ......
Page 2: ......
Page 60: ...www baldormotion com 3 44 Basic Installation MN1943 ...
Page 102: ...www baldormotion com 5 28 Input Output MN1943 ...
Page 136: ...www baldormotion com 7 8 Troubleshooting MN1943 ...
Page 172: ...www baldormotion com 8 36 Specifications MN1943 ...
Page 188: ...www baldormotion com B 6 Control System MN1943 ...
Page 204: ...www baldormotion com C 16 Mint Keyword Summary MN1943 ...
Page 216: ...Index MN1943 ...
Page 218: ...www baldormotion com Comments MN1943 Thank you for taking the time to help us ...
Page 219: ......
Page 220: ......