www.baldormotion.com
Input / Output 5-13
MN1943
TH1
R
fixed
MotiFlex
e
100
TH2
1
2
Motor
Example 1:
Motor maximum temp. = 130 °C
R
T
= 6 k
Ω
@ 130 °C
R
T
> 3.2 k
Ω
, so R
fixed
not required.
Example 2:
Motor maximum temp. = 130 °C
R
T
= 2 k
Ω
@ 130 °C
Add R
fixed
= 1.2 k
Ω
, so that R
T
+ R
fixed
>= 3.2 k
Ω
,
Note: To remove the trip, R
T
+ R
fixed
must reduce
to less than 2.8 k
Ω
.
R
T
Figure 53 - Using a thermistor controlled motor overtemperature output
Use a shielded twisted pair for the motor temperature connection, with the overall cable shield
(screen) connected to the metal backplane or signal cable management bracket (section A.1.6).
The
state
of
the
motor
overtemperature
input
can
be
read
using
the
MOTORTEMPERATURESWITCH
keyword. The resulting behavior of the MotiFlex
e
100 can be
controlled using the
MOTORTEMPERATUREMODE
keyword. See the Mint help file for details.
Summary of Contents for MotiFlex e100
Page 1: ......
Page 2: ......
Page 60: ...www baldormotion com 3 44 Basic Installation MN1943 ...
Page 102: ...www baldormotion com 5 28 Input Output MN1943 ...
Page 136: ...www baldormotion com 7 8 Troubleshooting MN1943 ...
Page 172: ...www baldormotion com 8 36 Specifications MN1943 ...
Page 188: ...www baldormotion com B 6 Control System MN1943 ...
Page 204: ...www baldormotion com C 16 Mint Keyword Summary MN1943 ...
Page 216: ...Index MN1943 ...
Page 218: ...www baldormotion com Comments MN1943 Thank you for taking the time to help us ...
Page 219: ......
Page 220: ......