Section 1
General Information
4-6 Programming & Operation
MN718
Program Mode
The Program Mode is used to:
1.
Enter motor data.
2.
Autotune the motor.
3.
Customize the drive (Control and Motor) parameters to your application.
From the Display Mode press the PROG key to access the Program Mode.
Note: When a parameter is selected, alternately pressing the Disp and Prog keys
will toggle between the Display Mode and the selected parameter. When a
parameter is selected for programming, the keypad display gives you the
following information:
Parameter Status
Parameter
Value and Units
Parameter Status. All programmable parameters are displayed with a “P:” in the lower
left corner of the keypad display. If a parameter is displayed with a “V:”, the parameter
value may be viewed but not changed while the motor is operating. If the parameter is
displayed with an “L:”, the value is locked and the security access code must be entered
before its’ value can be changed.
Parameter Blocks Access for Programming
Use the following procedure to access parameter blocks to program the control.
Action
Description
Display
Comments
Apply Power
Keypad Display shows this
opening message.
Logo display for 5 seconds.
If no faults and programmed for
LOCAL operation.
Display mode.
If no faults and programmed for
REMOTE operation.
If fault is displayed, refer to the
Troubleshooting section of this
manual.
Press PROG key
Press ENTER to access Preset
Speed parameters.
Press
Y
or
B
key
Scroll to the ACCEL/DECEL
block.
Press ENTER to access Accel
and Decel rate parameters.
Press
Y
or
B
key
Scroll to the Level 2 Block.
Press ENTER to access Level 2
Blocks.
Press ENTER key
First Level 2 block display.
Press
Y
or
B
key
Scroll to Programming Exit menu.
Press ENTER to return to Display
mode.
Press ENTER key
Return to display mode.