Section 1
General Information
3-4 Receiving & Installation
MN718
Figure 3-27 Process Mode Connection Diagram
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Enable
Forward
Reverse
Table Select
Speed/Torque
Process Mode Enable
External Trip
Opto Input Common
Programmable 0–5V Output (Factory Preset: Speed)
J1
ANALOG GND
ANALOG INPUT 1
POT REFERENCE
ANALOG INPUT +2
ANALOG INPUT –2
ANALOG OUT 1
ANALOG OUT 2
Opto Out Common
OPTO OUT #1
OPTO OUT #2
OPTO OUT #3
OPTO OUT #4
1
2
3
4
5
6
7
Programmable 0–5V Output (Factory Preset: Current)
Terminal Tightening Torque = 7 Lb-in (0.8 Nm).
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
23
24
25
26
27
28
29
COMMON
+24VDC
A
A
B
B
INDEX
INDEX
+5VDC
OPTO IN POWER
OPTO OUT #1 RETURN
OPTO OUT #2 RETURN
OPTO OUT #3 RETURN
OPTO OUT #4 RETURN
COMMON
A
A
B
B
INDEX
INDEX
Not Used
Encoder
Input
Note 5
Buffered
Encoder
Output
Note 6
Jog
Fault Reset
5k
W
Command Pot
Note 2
Note 1
±
5VDC,
±
10VDC or 4-20mA
Note 3
Note 4
Refer to Figure 3-32.
Notes:
1.
Refer to Analog Inputs.
2.
Refer to Analog Outputs.
3.
Refer to Opto Isolated Outputs.
4.
Refer to Figure 3-30 for 4-20mA.
5.
Refer to Encoder installation.
6.
Refer to Buffered Encoder Output.
J1-8
OPEN disables the control & motor coasts to a stop. Closed allows current to flow in the
motor and produce torque.
J1-9
CLOSED operates the motor in the Forward direction (with J1-10 open).
OPEN motor decels to stop (depending on Keypad Stop mode parameter setting).
J1-10
CLOSED operates motor in the Reverse direction (with J1-9 open).
OPEN motor decels to stop depending on Keypad Stop mode parameter setting.
J1-11
OPEN = TABLE 0, CLOSED = TABLE 1
J1-12
CLOSED, the control is in torque mode.
OPEN, the control is in velocity mode.
J1-13
CLOSED to enable the Process Mode.
J1-14
CLOSED places control in JOG mode. The control will only JOG in the forward
direction.
J1-15
CLOSED to reset a fault condition.
OPEN to run.
J1-16
OPEN causes an external trip to be received by control. The control will disable and
display external trip when programmed “ON”. When this occurs, the motor stop
command is issued, drive operation is terminated and an external trip fault is displayed
on the keypad display (also logged into the fault log).
If J1-16 is connected, you must set Level 2 Protection block, External Trip to “ON”.
J1-39 &
Jumper as shown to power the Opto Inputs from the in24VDC supply.
40