Section 7
Specifications, Ratings & Dimensions
Specifications, Ratings & Dimensions 7-1
MN718
Specifications:
Horsepower
1-50 HP @ 230VAC
1-500 HP @ 460VAC
1-150 HP @ 575VAC
Input Frequency
50/60 HZ
±
5%
Output Voltage
0 to Maximum Input VAC
Output Current
See Ratings Table
Service Factor
1.0
Duty
Continuous
Overload Capacity
Constant Torque Mode:
170-200% for 3 secs
150% for 60 secs
Variable Torque Mode:
115% for 60 secs
Operating Conditions:
Voltage Range: 230 VAC Models
460 VAC Models
575 VAC Models
180-264 VAC 3
O
60 Hz / 180-230 VAC 3
O
50 Hz
340-528 VAC 3
O
60 Hz / 340-460 VAC 3
O
50 Hz
495-660 VAC 3
O
60 Hz
Input Line Impedance:
3% Minimum Required
Ambient Operating Temperature:
0 to +40
°
C
Derate Output 2% per
°
C over 40
°
C to 55
°
C Max
Rated Storage Temperature:
– 30
°
C to +65
°
C
Enclosure:
NEMA 1:
E and EO (suffix) Models
NEMA 4X indoor: W (suffix) Models
Humidity:
NEMA 1:
10 to 90% RH Non-Condensing
NEMA 4X indoor: To 100% RH Condensing
Altitude:
Sea level to 3300 Feet (1000 Meters)
Derate 2% per 1000 Feet (303 Meters) above 3300 Feet