Page 40
Special Procedure
SP3: SC Identifi cation, cont’d
STA: 00
SC 00 PORTS USED: 1234
ENTER
IDENTIFY AIR CONTROL ?
SC 00 (SC INITIALIZED)
ENTER
IDENTIFY SC LOCATION ?
SC 01 (SC INITIALIZED)
ENTER
IDENTIFY SC LOCATION ?
SC 02 (SC INITIALIZED)
ENTER
IDENTIFY SC LOCATION ?
SC 16 (SC INITIALIZED)
ENTER
RESTART SYSTEM
INITIALIZATION COMPLETE
OFF/ON
SPECTRUM 100
IDLE
FROM
PREVIOUS
PAGE
EDIT VALUE:
MAGNET ID
MAGNET ID
MAGNET ID
MAGNET ID
9
Next, a prompt will ask you to identify a
fl uid controller to be designated as SC
00. To do this, pass a magnet over the cen-
tral LED (nearest mounting screw) location
on that installed fl uid controller.
When the magnetic identifi cation is success-
fully made, the second line of the display will
read “SC00 (SC INITIALIZED) for 3 seconds.
Then the program will move to the next bay
number and will repeat the magnetic identifi -
cation process. This will continue until all dis-
pensing bays in the system are identifi ed.
10
When all fl uid controllers are properly
identifi ed, including the air valve con-
troller, the prompt line displays the message
“RESTART SYSTEM, INITIALIZATION COM-
PLETE”.
Cycle the power switch off, then back on.
After a brief self test, the display will return to
home position: “SPECTRUM 100, IDLE”.
8
When all stations have been through the
port review scroll, the display will return
to a view of Station 00. Make one more scroll-
pass through the displays to be sure that all
ports are correctly set. Then, upon returning
to the view of Station 00, press “ENTER” to
continue.