Page 53
Diagnostic:
Error Codes and Messsages
Error Message and Code:
“Code 41”
“Valve-ON Error at Status Check”
Interpretation:
Console reports a valve-ON error
during a status check. Smart Control-
ler replacement is appropriate.
Step 1:
Replace the SC using procedure
“Replace Model 3120-030 Smart Con-
troller”
[Procedure RP5, page 59].
Then restart system.
Error Message and Code:
“Code 43”
“Valve Did Not Activate”
Interpretation:
Console detects that a valve did not
activate on command. Smart Control-
ler replacement is appropriate.
Step 2:
Replace the valve using procedure
“Replace Model 3120-032 Air Sole-
noid Valve or...”
[Procedure RP3,
page 58].
Then restart system.
Step 3:
Replace the Smart Controller using
procedure “Replace Model 3120-030
Smart Controller”
[Procedure RP5,
page 59].
Then restart system.
Step 1:
Complete the Procedure: “Verifi -
cation of Communication/Power
Wiring”
[Procedure RP9, page 61]