Page 15
Queuing Console Program Setup
29
With console power “OFF”, install the multipin
connector plug into the slot in the back face of
the console. Turn the console power “ON”. Also turn
“ON” the ticket printer, if used. Allow the console to
complete a self-test cycle, which should end at “SPEC-
TRUM 100 / IDLE”. If you observe an error message
at power-up, use the “ERROR DIAGNOSIS GUIDE”,
[
pages 47-56]
, before proceeding further. Call Balcrank
for factory assistance if required.
30
Edit some of the set-up fl uid parameters by
following the procedure “FLUID IDENTIFICA-
TION“,
[Procedure SP2, page 37-38]
. Step through
the procedure
without changing existing entries
except current tank amount.
Edit current tank
amount for each fl uid to show correct quanties now
in the tanks.
31
Leave console power “ON”. Complete procedure
“PIN ENTRY /REVISION”,
[Procedure BP9, page
35]
. Assist the customer in setting up personal I.D. PIN
codes for service technicians and managers. Have the
customer record and store PIN code information in a
secure place. A convenient record form is available
on page 67.
32
Cycle console power. If time and date are incor-
rect at console start-up, complete the procedure
“SET TIME/DATE”,
[Procedure SP5, page 42]
.
Purging Air and System Check Out
33
Check in the pump room to be sure that all air
supply valves to the pumps are open; for best
operation, set air regulators to 70-100 psi. Open all
fl uid shutoff valves in the system.
34
Have an attendant stand ready at station 1
with a 1-gallon calibrated measure container.
Authorize and dispense 1.0 gallons of fl uid 1 using the
procedure “NEW DISPENSE JOB”,
[Procedure BP2,
page 28]
. Observe for correct operation of the Ready
Light. Check to be sure the correct fl uid is dispensed
to station 1. If air is present in the fl uid piping, less
than 1.0 gallons will be dispensed. Therefore, repeat
this procedure until the dispensed quantity reaches
1.0 gallon and becomes consistent. Then dispose or
return the test fl uid.
35
Repeat procedure step 34 for each of the addi-
tional fl uids at station 1.
36
Repeat the procedure steps 34-35 at all other
dispensing stations.
37
Again, turn Power “OFF” and then “ON” at the
console. Allow the console to complete a self-
test cycle, which should end at “SPECTRUM 100 /
IDLE”. If you observe an error message at power-up,
use the troubleshooting guide, pages 47-56, before
proceeding further. Call Balcrank for factory assis-
tance if required.
38
Re-save all system set-up parameters by fol-
lowing the procedure “SYSTEM CONFIGURA-
TION“,
[Procedure SP6, page 43]
.
39
If the optional Host PC Interface (model 3120-
035) has been purchased, complete all software
installation per instructions supplied in the option
package, including test dispenses.
User Training and PIN Records
40
Review all console
basic procedures
with all
authorized customer users. Review
manage-
ment procedures
with the designated Spectrum
TM
user equipment manager.
41
Installation is now complete and ready for dis-
pensing service.
Installation:
Step-by Step Procedure
It is strongly recommended that PIN
code identifi cation be set up and utilized
in all
Spectrum
TM
installations
. This
assures the full protection against
fl uid theft or mis-use which has been
provided in the product design.
NOTE