Table 46: CO Trunk Error Log Entries
Error
Type
Aux Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear
Value
0*
0
Any
Any
Any
test port GGGVSpp
sh r 1
1 (a)
57347
None
15 (b)
any
Port Audit Update
Test (#36)
18
0
busyout trunk
WARNING
OFF
release trunk
grp#/mbr#
130(c)
None
WARNING
ON
test port GGGVSpp
sh r 2
257 (a)
50176
None
513 (a)
57364
None
MAJ/MIN/
WRN**
ON
769 (a)
57392
None
MAJ/MIN/
WRN**
OFF
1025 (e)
Any
Demand Diagnostic
Test (#3)
MAJ/MIN/
WRN**
OFF
test port GGGVSpp
sh r 2
1281 (e)
Any
Demand Diagnostic
Test (#3)
MAJ/MIN/
WRN**
ON
test port GGGVSpp
sh r 3
1537
Dial Tone Test (#0)
MAJ/MIN/
WRN**
OFF
test port GGGVSpp l
r 2
2561 (d)
57345
None
2817 (a)
57360
None
2817 (a)
57393
None
2817 (d)
57484
Dial Tone Test(#0)
MAJ/MIN/
WRN
OFF
test port GGGVSpp l
r 1
3073 (d)
57376
None
3329 (d)
57408
None
3329 (d)
57484
Dial Tone Test(#0)
MAJ/MIN/
WRN
OFF
test port GGGVSpp l
r 1
3585 (d)
57424
None
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
**Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
Summary of Contents for Media Gateway G350
Page 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Page 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Page 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...