Avaya Communication Manager controlled maintenance
MG-DS1 (DS1 Interface Media Module)
192
Maintenance of the Avaya G350 Media Gateway
June 2004
FAIL
The remote DS1 endpoint is out-of-service.
1
1794
FAIL
The MG-DS1 Interface Media Module detects a Line Loopback Alarm
(LLB).
If the DS1-M interface Media Module connects to a T1 facility, call the
vendor of the T1 carrier to diagnose the remote DS1 endpoint.
If the MG-DS1 interface Media Module connects directly to a switch, call
the system technician of the remote switch to diagnose the DS1 endpoint.
If the MG-DS1 interface Media Module connects directly to a line-side
terminating device (for example, a PRI terminal adapter), call the vendor of
the terminating device to diagnose the equipment.
1795
FAIL
The MG-DS1 Interface Media Module detects a Payload Loopback Alarm
(PLB). If the MG-DS1 Interface Media Module connects to a leased T1
facility, call the vendor of the T1 carrier to diagnose the remote DS1
endpoint. If the MG-DS1 Interface Media Module connects directly to
another DS1 board, call the system technician of the remote switch to
diagnose the DS1 endpoint. If the MG-DS1 Interface Media Module
connects directly to a line-side terminating device such as a PRI terminal
adapter contact the vendor of the terminating device to diagnose the
equipment.
PASS
Remote DS1 endpoint is in-service. Neither a Blue alarm nor a Line
Loopback alarm nor a Payload Loopback Alarm is detected by the MG-
DS1 Interface Media Module.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the
add ds1
GGGVS
command to administer the MM-DS1 interface if it is not already
administered.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then use the
busyout board
command.
Use the
reset board
command.
Use the
release busy board
command.
Use the
test board long
command.
This should re-establish the linkage between the internal ID and the port.
Table 110: TEST #139 Blue Alarm Inquiry Test 2 of 2
Error
Code
Test
Result
Description/ Recommendation