Avaya Communication Manager controlled maintenance
WAE-PORT (Wideband Access Endpoint Port)
230
Maintenance of the Avaya G350 Media Gateway
June 2004
Error Log Entries and Test to Clear Values
Notes:
•
The wideband access endpoint has been busied out by a
busyout access-endpoint
extension
command. No calls can be made to this extension.
•
The Media Module has been removed or has been insane for more than 11-minutes. To clear the
error, reinsert or replace the Media Module.
•
The Interface Media Module has failed. See MG-DS1.
•
The Port Audit and Update Test (#36) failed due to an internal system error. Enter
status
access-endpoint
extension and verify the status of the port. If the wideband access endpoint
port is out of service, enter
release access-endpoint
extension to put it back into service.
Retry the test command.
Table 127: Wideband Access Endpoint Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0*
0
Any
Any
Any
test access-endpoint
extension sh r 1
18(a)
0
busyout access-
endpoint
WARNING
OFF
release access-endpoint
extension
130(b)
None
WARNING
ON
test access-endpoint
extension
1793(e)
None
test board GGGVSpp
long
3840(f)
Any
Port Audit and Update
(Test #36)
*
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Summary of Contents for Media Gateway G350
Page 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Page 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Page 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...