Avaya Communication Manager controlled maintenance
DIG-LINE (Digital Line)
124
Maintenance of the Avaya G350 Media Gateway
June 2004
•
Internal system error. No action is necessary.
•
There is a problem with the voice terminal EEPROM. When the voice terminal is repaired the
alarm will be resolved with the passing of time.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing error codes associated with
the Voice and Control Channel Local Looparound Test, for example, you may also clear errors generated
from other tests in the testing sequence.
Table 65: Order of Investigation
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND*
Digital Terminal Remote Looparound Test (#1201)
Note
:
This Test ABORTS
X
D
Voice and Control Channel Local Looparound Test
(#13)
Note
:
This Test ABORTS
X
ND
Digital Line NPE Crosstalk Test (#9)
Note
:
This Test ABORTS
X
ND
Digital Line Electronic Power Feed Test (#11)
X
ND
DIG-LINE Station Lamp Updates Test (#16)
X
X
ND
Station (Digital) Audits Test (#17)
X
X
ND
*D = Destructive; ND = Nondestructive