Avaya Communication Manager controlled maintenance
XXX-BD (Common Port Media Module)
Maintenance of the Avaya G350 Media Gateway
237
June 2004
Control Channel Looparound Test (#52)
This test queries the Media Module for its vintage to verify angel communication.
Table 134: TEST #52 Control Channel Looparound Test
Error
Code
Test
Result
Description/ Recommendation
None
2100
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The test failed because the Media Module failed to return the Media
Module code or vintage.
Retry the command for a maximum of 5 times.
If the test still fails, use the
busyout board
,
reset board
, and
release
busy board
commands, and then retest.
If the problem continues, replace the Media Module.
Run the test again.
PASS
Communication with this Media Module is successful.
Any
NO
BOARD
This is normal if the test is being done when (a) the board is not physically
in the system or (b) the system is booting up. Otherwise, there is some
inconsistency between the physical configuration and the data kept in the
system.
Verify that the board is physically in the system.
Verify that the system is not in a stage of booting up.
Retry the command at 1-minute intervals for a maximum of 5 times.