Avaya Communication Manager controlled maintenance
TIE-DS1 (DS1 Tie Trunk)
228
Maintenance of the Avaya G350 Media Gateway
June 2004
2000
FAIL
Response to the seizure message was not received within the allowable
time period.
Enter the
list configuration board GGGVS
command. Eventually,
the board and all of its ports will be taken out of service and extraneous
on-board alarms will be generated. Replace the Media Module.
Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen
matches the trunk type administered on far-end switch.
Look for MG-DS1 errors in the hardware error log. If present, refer to
the MG-DS1 Maintenance documentation.
Retry the test at 1-minute intervals for a maximum of 5 times.
PASS
The trunk can be seized for an outgoing call.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
Check to ensure that the board translations are correct. Use the
list
config
command, and resolve any problems that are found.
If the board was found to be correctly inserted in step 1, use the
busyout board
command.
Use the
reset board
command.
Use the
release busy board
command.
Use the
test board long
command. This should re-establish the
linkage between the internal ID and the port. If this is not the case, check
to see that there is a valid board inserted.
*Earlier G1 Software Versions reported Error Code 2053 as a FAIL.
Table 125: TEST #136 DS1 Tie Trunk Seizure Test 3 of 3
Error
Code
Test
Result
Description/ Recommendation
3 of 3