Avaya Communication Manager controlled maintenance
DID-TRK (Direct Inward Dial Trunk)
112
Maintenance of the Avaya G350 Media Gateway
June 2004
Notes:
See also the preceding section on trunk problems without errors or alarms.
•
This condition occurs when the tone detector times out waiting for digits. Change
wink/immediate-start parameter to wink/immediate-start and rotary/tone-dial parameters.
1
Verify trunk administered wink/immediate-start parameter.
2
Test trunk using BUTT set.
3
Refer problem to CO.
•
Rotary dial before wink
—
This condition occurs when the CO starts dialing before the PBX
sends wink on a wink-start trunk.
1
Verify trunk administered wink/immediate-start parameter.
2
Refer problem to CO.
•
Rotary dial too early
—
This condition occurs when the CO starts dialing too soon after seizure
on an immediate-start trunk.
1
Verify trunk administered wink/immediate-start parameter.
2
Refer problem to CO.
•
Rotary dial pulse during wink
—
This condition occurs when the CO sends rotary dial digits too
soon after seizure on a wink-start trunk.
1
Verify trunk administered wink/immediate-start parameter.
2
Refer problem to CO.
•
This is a software audit error that does not indicate any hardware malfunction. Run Short Test
Sequence and investigate associated errors (if any).
•
This error type indicates that the Media Module has been removed or has been insane for more
than 11 minutes. To clear the error, reinsert or replace the Media Module.
•
Rotary dial pulse on-hook longer than 105 msec
—
Break between rotary pulses is too long.
1
Test trunk by performing an incoming test call.
2
Refer problem to CO.
•
Rotary dial rate below 8 pulses/sec
—
More than 135 msec between two successive breaks.
1
Verify trunk administered interdigit-timing parameters.
2
Refer problem to CO.
•
Rotary dial rate above 12 pulses/sec
—
Less than 75 msec between two successive breaks.
1
Verify trunk administered interdigit-timing parameters.
2
Refer problem to CO.
•
Digit detection
—
CO is starting new rotary dial digit within 150 msec of previous digit.
1
Verify trunk administered interdigit timing parameters.
2
Refer problem to CO.