Avaya Communication Manager controlled maintenance
DIG-LINE (Digital Line)
126
Maintenance of the Avaya G350 Media Gateway
June 2004
FAIL
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
PASS
Electronic Power Feed Test passed. The message to turn on the power to
the station was successfully sent to the port.
Although this test will never actually return a FAIL result except for the
Internal system error
described above, it will log an error indicating the
real results of the test. Check the Error Log for any entries with Error Types
767 or 769 after the test completes.
If Error Type 767 appears in the Error Log, this indicates that the test
sensed no problems with the power to the station. To verify that the station
is powered up correctly, run a self-test on the station and check that all the
feature buttons are operating.
If Error Type 769 appears in the Error Log, this indicates some problem
with the power to the station. Check for a short in the wiring, a damaged
jack, a defective voice terminal, or an incorrect type of terminal.
Any
NO
BOARD
The test could not relate the internal ID to the port.
Check to ensure that the board translations are correct. Translate the board,
if necessary.
Use the
busyout board
command.
Use the
reset board
command.
Use the
release busy board
command.
Use the
test board
command. This should re-establish the linkage
between the internal ID and the port.
If the problem persists, replace the circuit pack.
Table 66: TEST#11 Digital Line Electronic Power Feed Test 2 of 2
Error
Code
Test
Result
Description/ Recommendation
2 of 2