Avaya Communication Manager controlled maintenance
ALARM-PT (ALARM PORT)
Maintenance of the Avaya G350 Media Gateway
75
June 2004
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL
The port’s battery feed chip is unable to supply sufficient power to sense the
external device alarm. This may occur when the test is performed at the
same time that the external device contact closure occurred.
Enter
test external-device-alarm port GGGVSpp
to determine if the
port is reporting an EXT-DEV failure before retesting. Wait until the port
has no EXT-DEV failure before retesting.
Retry the command at 1-minute intervals for a maximum of 5 times.
PASS
The port’s battery feed chip is able to provide power to the external device
alarm to detect contact closure.
Table 32: TEST #35 Battery Feed Test 2 of 2
Error
Code
Test
Result
Description/Recommendation
2 of 2