Avaya Communication Manager controlled maintenance
AN-LN-PT (Analog Line Port)
Maintenance of the Avaya G350 Media Gateway
83
June 2004
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and translations with information in
the software.
Table 38: TEST #36
Station Status and Translation Audits and Updates 1 of 2
Error
Code
Test
Result
Description/ Recommendation
ABORT
Necessary system resources could not be allocated to run this test.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
1004
ABORT
A valid call seized the port during the test and aborted the test.
Use the display board GGGVSpp command to determine the station
extension.
Use the
status station
extension
command to determine the service
state of the port.
If the port is in use, wait until the port is idle before testing. Retry the
command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
1005
ABORT
This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ignored.
1006
ABORT
The port is out-of-service. The
busy station
extension
command has
been given to this port.
Look for error type 18 (port busied out) for this port. If this error is
present, release the port (
release station extension
), and run the test
again.
Make sure that the terminal is connected and in service, and then retest.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
System resources required to run this test are not available.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
1
FAIL
The switchhook audit failed. This result does not indicate a hardware
problem. The other updates were not performed because of this failure.
This may occur if the audit is performed at the same time the terminal
equipment goes off-hook.
Use the
status station
extension
command to determine when the
port is available.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to fail, escalate the problem.
1 of 2