Avaya Communication Manager controlled maintenance
MG-ICC (Internal Call Controller)
218
Maintenance of the Avaya G350 Media Gateway
June 2004
MG-ICC (Internal Call Controller)
This maintenance object monitors the H.323 link between the S8300 Media Server running as an LSP and
the primary call controller. It logs errors when the keep alive messages that are exchanged between the
servers fail. These messages indicate the status of the H.323 link between the two. If the keep alive
messages are active all is well; if not, an error is logged.
Error log entry and test to clear value
Notes:
•
Error Type 1
: this error type indicates a failure of the H.323 link keep alive messages between
the LSP and primary call controller. This is an indication that the LAN or the primary call
controller is down.
System Technician-Demanded Tests:
Descriptions and Error Codes
There are no System Technician-Demanded Tests associated with this MO.
Table 119: MG-ICC (Internal Call Controller)
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run*
Full Name of MO
MG-ICC
MAJOR
None
INTERNAL CALL
CONTROLLER
Note: You must consult local records for the location and designation of the equipment rack
where the G350 is mounted.
Table 120: MG-ICC error log entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
1(a)
None
MAJOR
OFF
Summary of Contents for Media Gateway G350