Avaya Communication Manager controlled maintenance
DID-TRK (Direct Inward Dial Trunk)
114
Maintenance of the Avaya G350 Media Gateway
June 2004
Port Diagnostic Test (#35)
This test checks a port’s battery feed circuitry for on-/off-hook detection, battery shutdown, and battery
reversal (wink) capabilities.
Table 59: TEST #35 Port Diagnostic Test 1 of 2
Error
Code
Test
Result
Description/ Recommendation
ABORT
System resources required to run this test were not available.
Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test were not available. The port may
be busy with a valid call.
Enter
display port GGGVSpp
command to determine the trunk
group/member number of the port. Use the
status trunk
command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
If the port status is active but the port is not in use (no calls), check the error
log for Error Type 513. The port may be locked up.
If the port status is idle, busyout and release the trunk, and retry the
command at 1-minute intervals a maximum of 5 times.
If the test continues to abort, check for wiring errors toward the CO which
may cause the trunk to lock up.
If the wiring is good and the test continues to abort, replace the circuit pack.
1004
ABORT
The port was seized by a valid call during the test.
Enter
display port GGGVSpp
to determine the station extension,
attendant number, or trunk group/member number of the port. Use the
status station
,
status attendant
, or
status trunk
command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
Retry the command at 1-minute intervals a maximum of 5 times.
1018
ABORT
Test disabled via administration. Verify that the
Maintenance Tests?
field on the Trunk Group Form is set to
n
. To enable the test, use the
change trunk-group x
command (x is the trunk group number). Then
change the entry in the
Maintenance Tests?
field to
y
.
2000
ABORT
Response to the test was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals a maximum of 5 times.
1 of 2