Avaya Communication Manager controlled maintenance
MG-DS1 (DS1 Interface Media Module)
214
Maintenance of the Avaya G350 Media Gateway
June 2004
1 to 17
(cont.)
FAIL
(cont’d.)
If the MM-DS1 connects to a line-side terminating device such as a PRI
terminal adapter:
1
Retry the command at 1-minute intervals for a maximum of
5 times.
2
Enter the
list measurement ds1-log GGGVS
command
to read the error seconds measurement.
3
Verify that the switch DS1 and the line-side terminating
device are administered using the same signaling mode,
framing mode, and line coding.
4
Investigate the maintenance status of the line-side
terminating device. Refer to the ’Line-Side Terminating
Device Operating Manual’ for information.
5
Contact the vendor of the line-side terminating device to
diagnose the equipment.
6
Check the physical connection of the MG-DS1 interface
Media Module to the terminating device, and check the
premise distribution system (or the intra-premise wiring) for
physical connection failures.
7
Replace the local MG-DS1 interface Media Module and
repeat the test.
PASS
No Misframe alarm is detected on the MM-DS1 Interface Media Module.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the
add ds1
GGGVS
command to administer the MM-DS1 interface if it is not already
administered.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then use the
busyout board
command.
Use the
reset board
command.
Use the
release busy board
command.
Use the
test board long
command.
This should re-establish the linkage between the internal ID and the port.
Table 116: TEST #145 Misframe Alarm Inquiry Test 3 of 3
Error
Code
Test
Result
Description/ Recommendation
3 of 3
Summary of Contents for Media Gateway G350
Page 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Page 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Page 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...