G350 traps
G350 traps and resolutions
Maintenance of the Avaya G350 Media Gateway
295
June 2004
avayaG350
64
lntPolicyAccessControlViolationFit
Policy
Warning
A packet has violated a policy rule on the specified
interface. The trap includes information about the
slot where the event occurred. The id of the rule
that was violated in the current rules table, and the
quintuplet that identifies the faulty packet.
This trap will not be sent at intervals smaller than
one minute for identical information in the
varbinds list variables.
avayaG350
68
lntUnAuthorizedAccessEvent
An attempt has been made to logon to the device
with an invalid userid/password.
avayaG350
70
ipArpViolationTrap
avayaG350
30
wanPhysicalAlarmOn
Wan
Critical
An E1/T1 serial cable has been disconnected.
avayaG350
31
wanPhysicalAlarmOff
Wan
Notification
An E1/T1 serial cable has been reconnected.
avayaG350
32
wanLocalAlarmOn
Wan
Error
A local alarm (such as LOS) has been generated.
avayaG350
33
wanLocalAlarmOff
Wan
Notification
A local alarm (such as LOS) has been cleared.
avayaG350
34
wanRemoteAlarmOn
Wan
Error
A remote alarm (such as AIS) has been generated.
avayaG350
35
wanRemotetAlarmOff
Wan
Notification
A remote alarm (such as AIS) has been cleared.
avayaG350
36
wanMinorAlarmOn
Wan
Warning
avayaG350
37
wanMinorAlarmOff
Wan
Notification
avEntTraps
1
avEntFanFlt
Temp
There is a faulty fan on the device.
1
Verify there are faults in the system. Use
the Avaya G350 Media Gateway CLI
command
show faults
to display any
faults on the G350.
2
If there is a fan/temperature fault, check
to see if the fans are working, and/or if
there is sufficient space around the G350
for air circulation.
3
Maintenance software monitors voltages
applied to the Media Modules and other
components of the G350, and compares
these to the general power supply unit
(PSU) status bit. If none of these voltages
are out of tolerance, but the PSU status
indicates failure, this generates the fan
fault, which will be indicated in the
show faults
command output. Replace
the entire G350. Fans and the PSU are
not field replaceable.
avEntTraps
2
avEntFanOk
Temp
Notification
A faulty fan has returned to normal functioning.
Table 159: G350 Traps and Resolutions 2 of 12
Enterprise
Trap
ID
Name
Msg
Facility
Severity
Description / Resolution
2 of 12