background image

Alcatel-Lucent OmniAccess 8550

WEB SERVICES GATEWAY | RELEASE 2.0

I N S T A L L A T I O N   G U I D E

Summary of Contents for OmniAccess 8550

Page 1: ...Alcatel Lucent OmniAccess 8550 WEB SERVICES GATEWAY RELEASE 2 0 I N S T A L L A T I O N G U I D E ...

Page 2: ...on without the prior written consent of Alcatel Lucent shall be at the customer s sole risk The customer hereby agrees to defend and hold Alcatel Lucent harmless from any claims for loss cost damage expense or liability that may arise out of or in connection with the use sale license or other distribution of the products in such applications This document may contain information regarding the use ...

Page 3: ...enarios a description of installation site requirements and guidelines a description of 8550 WSG technical and regulatory specifications how to install and connect the 8550 WSG how to power up and power down the 8550 WSG how to locate and interpret the 8550 WSG LEDs how to replace 8550 WSG hardware components See the OmniAccess 8550 WSG Configuration and Administration Guide for information about ...

Page 4: ...an numerals You must complete all of the substeps before you proceed to the next step Example of a procedure The following procedure includes a step with options and a step with substeps 1 You must perform this step 2 This step offers two options You must choose one of these options Danger Danger indicates that the described activity or situation may result in serious personal injury or death Warn...

Page 5: ...ss 8550 WSG Installation Guide Release 2 0 v September 2007 3HE03334AAAATQZZA Edition 02 a This is an option b This is another option 3 You must perform each of these substeps i This is the first substep ii This is the second substep ...

Page 6: ...Preface vi Alcatel Lucent OmniAccess 8550 WSG Installation Guide Release 2 0 September 2007 3HE03334AAAATQZZA Edition 02 ...

Page 7: ...stem General precautions If the 8550 WSG sustains damage requiring service disconnect the 8550 WSG from the AC electrical outlet and refer servicing to an authorized service provider Examples of damage requiring service include the following The power cord extension cord or plug has been damaged Liquid has been spilled on the 8550 WSG or an object has fallen into it The 8550 WSG has been exposed t...

Page 8: ...he installation and routine maintenance of the 8550 WSG must be performed by individuals who are knowledgeable about the procedures precautions and hazards associated with equipment containing hazardous energy levels Power down the 8550 WSG and disconnect all AC power cords before removing any access covers for non hot plug areas Do not replace non hot plug components while power is applied to the...

Page 9: ...cord by the plug Make sure that the total ampere rating of all products plugged into an extension cord or power strip does not exceed 80 of the ampere ratings limit for the extension cord or power strip Do not disable the power cord grounding plug The grounding plug is an important safety feature Plug the power cord into a grounded earthed electrical outlet Power supplies Installation of the 8550 ...

Page 10: ...equipment damage when installing or servicing UPS products observe the following The installation of options and routine maintenance of UPS products must be performed by trained service technicians who are knowledgeable about the procedures precautions and hazards associated with AC power products Hardwired UPS products require a direct connection to a dedicated AC branch circuit AC mains Connecti...

Page 11: ...e short external contacts or dispose of the battery in fire or water Replace the battery only with the spare battery designated for this product Do not dispose of batteries with the general household waste To forward them to recycling or proper disposal use the public collection system Manual handling of equipment To reduce the risk of personal injury or damage to the equipment observe the followi...

Page 12: ... careful when pressing the component rail release latches and sliding the component into the rack The slide rails could pinch your fingertips You load the rack from the bottom up and load the heaviest item into the rack first You do not attempt to move equipment racks without adequate assistance due to their height and weight You do not attempt to move an equipment rack on an incline that is great...

Page 13: ...ng methods to prevent electrostatic discharge Use one or more of the following methods when you handle or install electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 resistance in the ground cords To provide proper grounding wear the strap snug against the skin Use he...

Page 14: ...nes Balance the server power load between available AC supply branch circuits Do not allow the overall system AC current load to exceed 80 of the branch circuit AC current rating Do not use common power outlet strips Provide a separate electrical circuit for the 8550 WSG Warning To reduce the risk of personal injury fire or damage to equipment do not overload the AC supply branch circuit that prov...

Page 15: ...ocedure iv Mandatory regulations vii General precautions vii Precautions for installing and maintaining the 8550 WSG viii Power cords ix Power supplies ix UPS Products x Batteries xi Manual handling of equipment xi Rack installation precautions xii Preventing electrostatic discharge and safety procedures xii Grounding methods to prevent electrostatic discharge xiii Guidelines for branch circuits x...

Page 16: ...t panel 1 8 Rear panel 1 9 Power management 1 9 Cooling 1 9 Hot pluggable hard drives 1 10 Ports 1 10 Cable management arm 1 11 1 4 Installation tasks 1 12 2 Site Preparation 2 1 2 1 Before you begin 2 2 2 2 Cable requirements 2 2 Types of cables 2 2 2 3 Selecting an appropriate location for the chassis 2 3 Keeping the chassis cool 2 3 Environmental considerations 2 3 3 Installing and connecting t...

Page 17: ... High Availability ports 3 23 Procedure 3 9 To connect the 8550 WSG High Availability ports 3 23 3 11 Configuring the PC that connects to the 8550 WSG Management Portal 3 24 Procedure 3 10 To configure the 8550 WSG IP address on the PC that connects to the 8550 WSG Management Portal 3 24 3 12 Connecting the 8550 WSG management port to a router or network switch 3 25 Procedure 3 11 To connect the 8...

Page 18: ...assis specifications A 1 A 1 Chassis specifications A 2 Technical specifications A 2 Regulatory specifications A 3 B Replacing system components B 1 B 1 Field Replaceable Units B 2 B 2 Powering down the 8550 WSG B 2 Procedure B 1 To power down the 8550 WSG B 2 B 3 Replacing the 8550 WSG B 3 Procedure B 2 To remove the 8550 WSG from the rails B 3 B 4 Replacing the power supply B 4 Procedure B 3 To ...

Page 19: ...Access 8550 WSG Installation Guide Release 2 0 1 1 September 2007 3HE03334AAAATQZZA Edition 02 1 Overview 1 1 Introduction 1 2 1 2 8550 WSG deployment planning 1 2 1 3 Hardware description 1 8 1 4 Installation tasks 1 12 ...

Page 20: ...nning The 8550 WSG can be deployed to virtualize any combination of the following scenarios virtualized internal services for external consumption Internal web services are configured on the 8550 WSG and access is provided to external users such as partners virtualized external services for internal consumption External services are configured on the 8550 WSG to allow access to internal users inte...

Page 21: ...services virtualized by the 8550 WSG the following firewall configuration is necessary at Enterprise1 The external firewall must be configured to permit inbound web sessions to the 8550 WSG data port s The internal firewall must be configured to permit inbound web connections from the 8550 WSG to the WS App1 and WS App2 Web service clients at partner sites and individual external users access the ...

Page 22: ...rvices provided by a partner organization or individual external services For internal users to use services virtualized by the 8550 WSG the external firewall at Enterprise1 is configured to permit outbound web sessions from the 8550 WSG data ports The Enterprise1 8550 WSG is configured to transform and forward web service requests from internal client applications to use external web services Int...

Page 23: ...al external services Internal services for internal consumption The 8550 WSG can also be deployed within the network of an organization without partnering with other organizations You can configure the 8550 WSG in the local intranet only as shown in Figure 1 3 Internet Enterprise 1 WS Client App External Firewall SOAP SOAP 19308 LDAP Repository LDAP SOAP Internal Firewall DMZ 8550 WSG Individual e...

Page 24: ...es provided by a partner organization The firewalls at Enterprise1 are configured to permit both inbound and outbound web sessions to and from the 8550 WSG data ports and the 8550 WSG is configured to transform and forward web service requests from internal client applications to use both internal and external web services Internal 19416 LDAP SOAP WS Client App LDAP Repository WS App1 8550 WSG SOA...

Page 25: ...ity redundant configuration This type of configuration is optional You require two 8550 WSG nodes for this configuration so that one is the active node and the other is the standby node The two 8550 WSG nodes are connected over the HA link The HA link is the control link between the redundant nodes You use a crossover Gigabit Ethernet cable for the HA connection Enterprise 1 8550 WSG DMZ WS Client...

Page 26: ...on of the front panel components Figure 1 6 Front panel 19391 Web Client App HA link Web Service LDAP Repository 8550 WSG 8550 WSG SOAP HTTP Internal SOAP LDAP UID 1 1 2 3 4 5 6 7 8 PROC PROC OVER TEMP INTER LOCK ONLINE SPARE MIRROR PPM PPM PROC PROC POWER SUPPLY PCI RISER CAGE POWER SUPPLY DIMMS FANS 2 Exhaust vents for the cooling fans UID button Failsafe serial port System Insight Display Hot p...

Page 27: ...ooling is provided by interior fans The fans are paired in a redundant configuration The speed of the fans is automatically controlled and varies according to the measured temperatures within the 8550 WSG The 8550 WSG also contains a number of sensors that continuously monitor the interior temperature of the chassis The temperature measurements are used to provide information to the fans and there...

Page 28: ...550 WSG Management Portal user interface is accessible only through this port High Availability port The High Availability port is a Gigabit Ethernet port that is used to link the two 8550 WSGs to exchange control data and synchronize both 8550 WSGs Ethernet ports and port grouping The 8550 WSG contains four Gigabit Ethernet ports that provide connectivity from the 8550 WSG to the data network The...

Page 29: ...nel free of the cables used to connect to the rest of the network and thus allows a smaller footprint for the unit in the rack The cable management arm can be mounted for a left hand swing or a right hand swing When the cable management arm is mounted for a left hand swing it can be swung in or out without removing the arm or detaching any of the cables If you mount the arm for a right hand swing ...

Page 30: ...ist 19281 Warning Ensure you know the site requirements and safety precautions described in chapter 2 and the mandatory requirements chapter before performing any installation task Task Description See Procedure Unpack the 8550 WSG Unpack the 8550 WSG and verify that all the parts are available 3 1 Record the serial number of the 8550 WSG Find and record the serial number of the 8550 WSG 3 2 Ready...

Page 31: ... arm on the rack 3 6 Convert the cable management arm for a right hand swing If required convert the cable management arm for a right hand swing 3 7 Power up the 8550 WSG Turn on the power to the 8550 WSG and allow for the self tests 4 1 Configuring the PC that connects to the 8550 WSG Management Portal Before you initialize the 8550 WSG Management Portal you must connect a PC to the management po...

Page 32: ... 1 2 Equipment replacement procedure list Caution Do not open the top cover on the 8550 WSG If you do the Alcatel Lucent product warranty is voided Description See Procedure Powering down the 8550 WSG B 1 Removing the 8550 WSG from the rails B 2 Replacing the redundant power supplies and power cables B 3 Replacing a hard drive B 4 ...

Page 33: ...ccess 8550 WSG Installation Guide Release 2 0 2 1 September 2007 3HE03334AAAATQZZA Edition 02 2 Site Preparation 2 1 Before you begin 2 2 2 2 Cable requirements 2 2 2 3 Selecting an appropriate location for the chassis 2 3 ...

Page 34: ...anadian Interference Causing Equipment Regulations This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations In Europe the cables comply with the following EU Directives Low Voltage Directive 73 23 EEC EMC Directive 89 336 EEC Types of cables The 8550 WSG uses the following types of cables power cord two power cords are supplied crossover Ethe...

Page 35: ... in behind the rack Leave a minimum clearance of 121 9 cm 48 in from the back of the rack to the back of another rack or row of racks Keeping the chassis cool The 8550 WSG draws in cool air through the cooling fans exhaust vents on the front panel To prevent improper cooling do not block the vents Environmental considerations To ensure continued safe and reliable equipment operation install or pos...

Page 36: ...2 Site Preparation 2 4 Alcatel Lucent OmniAccess 8550 WSG Installation Guide Release 2 0 September 2007 3HE03334AAAATQZZA Edition 02 ...

Page 37: ...ber of the 8550 WSG 3 3 3 4 Installing the rails for the 8550 WSG in a rack 3 4 3 5 Attaching the 8550 WSG to the rails 3 7 3 6 Cabling the 8550 WSG 3 10 3 7 Installing the cable management arm 3 13 3 8 Converting the cable management arm for a right hand swing 3 15 3 9 Connecting the AC power cords to the 8550 WSG 3 22 3 10 Connecting the 8550 WSG High Availability ports 3 23 3 11 Configuring the...

Page 38: ...niAccess 8550 WSG Installation Guide Release 2 0 September 2007 3HE03334AAAATQZZA Edition 02 3 12 Connecting the 8550 WSG management port to a router or network switch 3 25 3 13 Connecting the 8550 WSG Ethernet data network ports to a router or network switch 3 26 ...

Page 39: ... one 15 ft crossover Ethernet cable if you ordered the High Availability bundle one rack installation kit per 8550 WSG including a rail assembly a cable management arm assembly screws cables straps and cable ties customer documentation including this guide and a license certificate Procedure 3 1 To unpack the 8550 WSG 1 Unpack the 8550 WSG shipping carton 2 Locate the materials and documentation n...

Page 40: ...550 WSG You can find the serial number at the top and rear of the 8550 WSG 2 Write down the serial number and store it 3 4 Installing the rails for the 8550 WSG in a rack Attach the rails in the service rack Procedure 3 3 To install the rails 1 Attach the rail mounts to the rack chassis as shown in Figure 3 1 Note In a High Availability configuration install a second set of rails in another locati...

Page 41: ...eptember 2007 3HE03334AAAATQZZA Edition 02 Figure 3 1 Attaching the rail mounts to the rack 2 Screw in the rail mounts as shown in Figure 3 2 and Figure 3 3 Front Front To release front side mounting bracket if it needs to be repositioned To release front side mounting bracket if it needs to be repositioned 19276 ...

Page 42: ...stalling and connecting the 8550 WSG 3 6 Alcatel Lucent OmniAccess 8550 WSG Installation Guide Release 2 0 September 2007 3HE03334AAAATQZZA Edition 02 Figure 3 2 Screwing the rail mounts into the rack 19277 ...

Page 43: ... the rail mounts into the rack 3 5 Attaching the 8550 WSG to the rails Attach the 8550 WSG to the service rack rails 19305 Note In a High Availability configuration attach a second 8550 WSG to the second set of rails you installed in Procedure 3 3 Connect the two 8550 WSGs with the 15 ft crossover Ethernet cable using the High Availability port as described in Procedure 3 5 ...

Page 44: ... into the rail mounts as shown in Figure 3 5 Warning 1 Stabilize the rack assembly before you slide the inner slides into the slide mounting brackets Warning 2 Keep the 8550 WSG parallel to the floor when you slide the inner slides into the slide mounting brackets Warning 3 Populate the rack from the bottom to the top based on equipment weight with the heaviest piece going at the bottom 19275 Warn...

Page 45: ...e 8550 WSG Alcatel Lucent OmniAccess 8550 WSG Installation Guide Release 2 0 3 9 September 2007 3HE03334AAAATQZZA Edition 02 Figure 3 5 Sliding the 8550 WSG into the mounts Front 2x To release inner slide lock to remove server 19278 ...

Page 46: ... 8550 WSG Use the supplied 15 ft crossover Ethernet cable with RJ 45 connectors to make this connection a connection from the management port to the network switch Use a straight Ethernet cable with RJ 45 connectors to make this connection a connection from the four Ethernet data ports to a network switch Use a straight through Ethernet cable with RJ 45 connectors for this connection Figure 3 6 sh...

Page 47: ...er 2007 3HE03334AAAATQZZA Edition 02 Figure 3 6 Standalone 8550 WSG port connections Note You can use the management port connection if you require only one connection to handle both management and data traffic 19389 UID Ethernet data network ports 3 4 5 6 Management port High Availability port Ethernet switch or Router ...

Page 48: ...dure 3 8 2 In a High Availability configuration connect the High Availability port on one 8550 WSG to the High Availability port on the other 8550 WSG as described in Procedure 3 9 3 Connect the management port to the router or network switch as described in Procedure 3 11 19390 UID UID Ethernet switch or router 2 Ethernet data network ports 3 4 5 6 Management port High Availability port 3 4 5 6 E...

Page 49: ...o install the cable management arm on the rack Procedure 3 6 To install the cable management arm 1 Attach the arm assembly to the rail bracket as shown in Figure 3 8 Figure 3 8 Attaching the arm assembly to the bracket 2 Position the arm assembly to receive the cables as shown in Figure 3 9 Note Use Procedure 3 7 to convert the cable management assembly from a left hand swing to a right hand swing...

Page 50: ...9 Positioning the arm assembly to receive the cables 3 Pull down the quick release levers on each side of the 8550 WSG and extend the 8550 WSG out on its rails as shown in Figure 3 10 Figure 3 10 Extending the 8550 WSG out on its rails 4 Arrange the cables as shown in Figure 3 11 Use the supplied cable straps and ties to secure the cables as required 19281 2x 19282 ...

Page 51: ...ack into the rack and lock the quick release levers 3 8 Converting the cable management arm for a right hand swing Use this procedure to convert the cable management arm for a right hand swing 1 3 2 4 Rear 19283 Warning To reduce the risk of personal injury be careful when pressing the quick release levers and sliding the 8550 WSG into the rack The sliding rails could pinch your fingers Caution Or...

Page 52: ...ment arm for a right hand swing 1 Detach the arm from the retaining bracket by pulling the pin and lifting the arm as shown in Figure 3 12 Figure 3 12 Detaching the arm from the bracket 2 Remove the spring from the arm brace as shown in Figure 3 13 Note After you configure the arm for a right hand swing you may have to remove the arm to access some components on the rear of the 8550 WSG 1 2 19284 ...

Page 53: ...E03334AAAATQZZA Edition 02 Figure 3 13 Removing the spring from the brace 3 Detach the other arm from its retaining bracket by pulling the pin and lifting the arm as shown in Figure 3 14 Figure 3 14 Detaching the other arm from the bracket 4 Unscrew and pull the arm assembly from its brace as shown in Figure 3 15 19285 1 2 19286 ...

Page 54: ...G Installation Guide Release 2 0 September 2007 3HE03334AAAATQZZA Edition 02 Figure 3 15 Pulling the arm assembly from its brace 5 Detach the flange as shown in Figure 3 16 Figure 3 16 Detaching the flange 6 Rotate the arm assembly 180o as shown in Figure 3 17 19287 2 1 2 1 19288 ...

Page 55: ...the 8550 WSG Alcatel Lucent OmniAccess 8550 WSG Installation Guide Release 2 0 3 19 September 2007 3HE03334AAAATQZZA Edition 02 Figure 3 17 Rotating the arm assembly 7 Re attach the flange as shown in Figure 3 18 Rotate 180 19289 ...

Page 56: ...8550 WSG Installation Guide Release 2 0 September 2007 3HE03334AAAATQZZA Edition 02 Figure 3 18 Re attaching the flange 8 Re attach the arm assembly as shown in Figure 3 19 Figure 3 19 Re attaching the arm assembly 9 Re insert the spring as shown in Figure 3 20 19290 19292 ...

Page 57: ...de Release 2 0 3 21 September 2007 3HE03334AAAATQZZA Edition 02 Figure 3 20 Re inserting the spring 10 Re attach the arm to the bracket as shown in Figure 3 21 Figure 3 21 Re attaching the arm assembly to the bracket 11 Screw the arm back to the bracket as shown in Figure 3 22 19293 1 2 19294 ...

Page 58: ...s described in Procedure 3 6 3 9 Connecting the AC power cords to the 8550 WSG Use this procedure to connect the two AC power cords to the 8550 WSG Procedure 3 8 To connect the AC power cords 1 Connect the power cords to the rear of the 8550 WSG 2 Install the power cord anchor on the handle of the power supply 3 Secure the cord to the cable management arm 4 Connect the power cord to the AC power s...

Page 59: ...ts 1 Run the crossover Ethernet cable from the High Availability port on the rear of one 8550 WSG to the High Availability port on the rear of the other 8550 WSG 2 Check the High Availability LEDs on the rear panel of the 8550 WSG to ensure the High Availability connection is working properly See chapter 5 for information on how to interpret LED status indicators Warning 1 Plug the power cord into...

Page 60: ... port on the 8550 WSG 2 Configure the PC LAN settings with the IP address of 192 168 1 2 and subnet mask of 255 255 255 0 3 Log in to the 8550 WSG Management Portal by typing http 192 168 1 1 8080 webportal in your browser address 4 Type the username admin 5 Type the password admin 6 Click on the Login button The 8550 WSG Management Portal appears with the Administration Node Status panel open 7 F...

Page 61: ...ing in you are asked to the accept the configuration changes Click OK 3 12 Connecting the 8550 WSG management port to a router or network switch Use this procedure to connect the 8550 WSG management port to a router or network switch Procedure 3 11 To connect the 8550 WSG management port to a router or network switch 1 After you have performed Procedure 3 10 remove the crossover cable that connect...

Page 62: ...s to a router or network switch Use straight through Ethernet cables for the connections a In a standalone configuration connect the required data ports ports 3 to 6 to the router or network switch as shown in Figure 3 6 b In a High Availability configuration make the following connections as shown in Figure 3 7 i Connect ports 3 and 5 of 8550 WSG 1 to router or network switch 1 ii Connect ports 4...

Page 63: ... Installation Guide Release 2 0 4 1 September 2007 3HE03334AAAATQZZA Edition 02 4 Getting started 4 1 Powering up the 8550 WSG 4 2 4 2 Initializing the 8550 WSG Management Portal 4 2 4 3 Logging out of the 8550 WSG Management Portal 4 4 ...

Page 64: ...n to the 8550 WSG Management Portal to initialize the system Procedure 4 2 To log in to the 8550 WSG Management Portal to initialize the system 1 Type http 192 168 1 1 8080 webportal in your browser address The 8550 WSG Management Portal login window appears as shown in Figure 4 1 Note 1 Before you log in to the 8550 WSG Management Portal for the first time perform Procedure 3 10 to configure the ...

Page 65: ... Figure 4 1 8550 WSG Management Portal login window 2 Type the username admin 3 Type the password admin 4 Click on the Login button The 8550 WSG Management Portal appears with the Administration Node Status panel open as shown in Figure 4 2 Figure 4 2 8550 WSG Management Portal after login 5 At this point the system is initialized ...

Page 66: ...g 8550 WSG hardware information managing 8550 WSG hardware managing users managing web service definitions managing session policies managing audit rollovers and schedules managing system logs managing system upgrades debugging reports See the OmniAccess 8550 WSG Configuration and Administration Guide available from the Help menu in the 8550 WSG Management Portal for information on how to perform ...

Page 67: ...Alcatel Lucent OmniAccess 8550 WSG Installation Guide Release 2 0 5 1 September 2007 3HE03334AAAATQZZA Edition 02 5 LEDs 5 1 LEDs 5 2 ...

Page 68: ...ont panel also contains the power on standby button LED and a Unit Identification LED for easy in rack identification and status indication Additionally the hard drives are equipped with LEDs to show their operational health System Insight Display LEDs The System Insight Display is part of the faceplate of the 8550 WSG and consists of LEDs that provide a visual indication of the general health of ...

Page 69: ...ther LEDs on the front panel Table 5 2 describes these LEDs Indicator State Description Online spare Off Green Amber Flashing amber There is no protection Protection is enabled A memory failure has occurred There is a memory configuration error Mirror Off Green Amber Flashing amber There is no protection Protection is enabled A memory failure has occurred There is a memory configuration error All ...

Page 70: ...ternal health Green The system is operating normally Amber The system is degraded See the System Insight Display LEDs description to identify the component in a degraded state Red The system is in critical state See the System Insight Display LEDs description to identify the component in a critical state 1 of 2 19376 UID 1 PROC PROC OVER TEMP INTER LOCK PPM PPM PROC PROC DIMMS FANS 2 Internal heal...

Page 71: ...y failure See the Systems Insight Display LEDs description to identify the component in critical state Network link activity 1 Green There is a network link Flashing There is a network link and activity Off There is no network link If the power is off view the rear panel RJ45 LEDs for the status Network link activity 2 Green There is a network link Flashing There is a network link and activity Off...

Page 72: ...50 WSG Installation Guide Release 2 0 September 2007 3HE03334AAAATQZZA Edition 02 Figure 5 3 Hard drive LEDs Table 5 3 Hard drive LEDs description Fault UID LED amber blue Online LED green 19378 LED Online LED green Fault UID LED amber blue ...

Page 73: ...een received for this drive To minimize the risk of data loss do not replace the drive until the expansion or migration is complete Do not remove the drive Removing the drive may terminate the current operation and cause data loss Flashing regularly 1 Hz Off The drive is rebuilding or it is part of an array that is undergoing capacity expansion or stripe migration Do not remove the drive If you re...

Page 74: ...nel of the 8550 WSG contains LEDs associated with the power supply network connections and the UID button Figure 5 4 shows the LEDs on the rear panel of the 8550 WSG Table 5 5 describes these LEDs Figure 5 4 Rear panel LEDs and buttons UID Power supply LED Network link activity 1 LED Network link activity 2 LED Unit identification button LED 19377 ...

Page 75: ...twork link If the power is off view the rear panel RJ45 LEDs for the status Network link activity 2 Green Flashing Off There is a network link There is a network link and activity There is no network link If the power is off view the rear panel RJ45 LEDs for the status Power supply Green Off The power supply is normal The system is off or the power supply has failed Unit Identification button Blue...

Page 76: ...5 LEDs 5 10 Alcatel Lucent OmniAccess 8550 WSG Installation Guide Release 2 0 September 2007 3HE03334AAAATQZZA Edition 02 ...

Page 77: ...Alcatel Lucent OmniAccess 8550 WSG Installation Guide Release 2 0 A 1 September 2007 3HE03334AAAATQZZA Edition 02 A 8550 WSG chassis specifications A 1 Chassis specifications A 2 ...

Page 78: ...n wide 66 07 cm 26 01 in long Weight with two hard drives installed 27 22 kg 60 lbs Rated input voltage 100 132 V ac or 200 240 V ac Rated input current 10 A when the line voltage is 100 132 V ac 4 9 A when the line voltage is 200 V ac Rated input frequency 50 to 60 Hz Rated input power 980 W at 100 V input 960 W at 200 V ac input Btus per hour input 3344 at 100 V ac to 120 V ac input 3277 at 200 ...

Page 79: ...ware alarm indicators Front panel unit identifier indicators Standards compliance HTTP 1 0 1 1 TLSv1 SSLv3 DES 3DES AES RC4 SHA 1 MD5 RSA DSA X509 Diffie Hellman SAML 2 0 SOAP 1 1 12 One 802 3ab GbE HA port XSLT 1 0 XPath 1 0 802 3u Specification Description 2 of 2 Specification Description EMC ICES 003 Class A Interference causing equipment standard for digital apparatus FCC Part 15 Class A FCC r...

Page 80: ...al requirements EN60950 1 Safety of information technology equipment IEC 60950 1 Information technology equipment Safety Part 1 General requirements AS NZS 60950 1 2001 Approval and test specification Safety of information technology equipment including electrical business equipment Telecommunications IEEE 802 3 Carrier Sense Multiple Access with Collision Detection CSMA CD access method and PHY L...

Page 81: ... Release 2 0 B 1 September 2007 3HE03334AAAATQZZA Edition 02 B Replacing system components B 1 Field Replaceable Units B 2 B 2 Powering down the 8550 WSG B 2 B 3 Replacing the 8550 WSG B 3 B 4 Replacing the power supply B 4 B 5 Replacing a hard drive B 5 ...

Page 82: ... the 8550 WSG Procedure B 1 To power down the 8550 WSG 1 If more than one 8550 WSG is installed in the rack press the UID button on the front panel of 8550 WSG that is being powered down The UID button LED on the front and rear panel of the 8550 WSG lights up blue Note Do not open the top cover on the 8550 WSG If you do the Alcatel Lucent product warranty is voided Danger To reduce the risk of per...

Page 83: ...r cords from the 8550 WSG The 8550 WSG is now without power B 3 Replacing the 8550 WSG Detach the 8550 WSG from the rails if you need to remove it from the rack Procedure B 2 To remove the 8550 WSG from the rails 1 Swing open the cable management arm and detach it from the rail bracket 2 Pull down the quick release levers on each side of the 8550 WSG 3 Extend the server from the rack until the ser...

Page 84: ...SG iii Slide out the faulty power supply unit from its bay Warning To reduce the risk of personal injury or equipment damage ensure that the rack is adequately stabilized before extending the 8550 WSG from the rack Warning 1 Ensure you are properly grounded See the mandatory requirements chapter for the recommended grounding methods to prevent electrostatic discharge Warning 2 To reduce the risk o...

Page 85: ...reen See chapter 5 for information on LEDs B 5 Replacing a hard drive Use this procedure to replace a hard drive Procedure B 4 To replace a hard drive 1 Remove a hard drive from its bay i Push down on the drive extraction handle tab on the front of the hard drive ii Lift the handle and pull it gently until the hard drive slides out 2 Install a hard drive into the empty hard drive bay i Insert the ...

Page 86: ...B Replacing system components B 6 Alcatel Lucent OmniAccess 8550 WSG Installation Guide Release 2 0 September 2007 3HE03334AAAATQZZA Edition 02 ...

Page 87: ...rvices oriented architecture SOA backbone element 8550 WSG Management Portal The GUI that provides the management interface of the 8550 WSG A AAA Authentication Authorization and Accounting authentication Authentication is the process of validating the digital credentials pertaining to a user s identity authorization The process of granting a user complete or restricted access to an object a resou...

Page 88: ...A s certificates D digital certificate A digital certificate is an electronic document issued by a certificate authority attesting to the validity of a user s public key Validity may expire after a period of time or may be revoked by a certificate authority by being placed in a revocation list DMZ Demilitarized Zone A network area subnetwork located between an internal network and an external netw...

Page 89: ...tallation removal or replacement in the field without cycling power HTTP HyperText Transfer Protocol HTTPS Secure HyperText Transfer Protocol Indicates that HTTP is to be used over an SSL protected connection An HTTPS connection uses a different default port 443 and an additional encryption authentication layer between HTTP and TCP It provides authentication and encrypted communication and is wide...

Page 90: ...ccess Protocol LDAP is a networking protocol for querying and modifying directory services that run over TCP IP M management interface The management interface is defined between two subsystems a management interface allows you to configure system components collect statistics and treat alarms O OAM operations administration maintenance P partner organization Two organizations that share web servi...

Page 91: ...ssaging framework which provides a message construct that can be exchanged over a variety of underlying protocols SOAP also defines a complete processing model that outlines how messages are processed as they travel through a path SSL secure sockets layer A protocol for transmitting private documents over the Internet SSL uses a cryptographic system that uses two keys to encrypt data a public key ...

Page 92: ...ormat specifically WSDL Other systems interact with the Web service in a manner prescribed by its description using SOAP messages typically conveyed using HTTP with an XML serialization in conjunction with other Web related standards WS web service WS client A user workstation that is configured with Web Services client software The WS client accepts user input and generates SOAP messages to the 8...

Page 93: ...ations A 3 removing B 3 serial number 3 3 shipping carton contents 3 3 technical specifications A 2 8550 WSG Management Portal configuring a PC 3 24 default password 4 2 initializing 4 2 logging in 4 2 logging out 4 4 login window 4 3 B batteries types used xi branch circuits guidelines xiv C cable management arm 1 11 arranging cables 3 15 converting for right hand swing 3 15 installing on rack 3 ...

Page 94: ...al services for external consumption and virtualized external services for internal consumption 1 6 internal services for internal consumption 1 5 virtualized external services for internal consumption 1 4 virtualized internal services for external consumption 1 3 E electrostatic discharge preventing xii European cable directive EMC 2 2 low voltage 2 2 F features hardware 1 2 Field Replaceable Uni...

Page 95: ... 5 5 6 internal health 5 4 location on front panel 5 2 location on hard drive 5 5 location on rear panel 5 8 network link activity 5 4 online 5 6 power on and system power 5 4 rear panel 5 8 5 9 5 9 5 9 rear panel network activity 5 9 rear panel power supply 5 9 rear panel unit identification 5 9 System Insight Display 5 2 unit identification 5 4 M management cable 1 11 hardware 1 2 N North Americ...

Page 96: ...when maintaining or installing viii general vii handling equipment xi installing viii maintaining viii power cords ix power supply ix rack installation xii UPS products x R rack installation precautions xii rear panel 1 9 S static discharge ESD xii System Insight Display LEDs LED descriptions 5 3 mirror 5 3 offline spare 5 3 U UPS when to use ix precautions UPS ...

Page 97: ...port http www alcatel lucent com osds documentation feedback alcatel lucent com Product manuals and documentation updates are available through the Alcatel Lucent Support Documentation and Software Download service at alcatel lucent com If you are a new user and require access to this service please contact your Alcatel Lucent sales representative ...

Page 98: ... 2007 Alcatel Lucent All rights reserved 3HE03334AAAATQZZA Edition 02 ...