FAIL
Test failed due to internal system error.
Retry the command at 1-minute intervals a maximum of 5 times.
PASS
Trunk translation has been updated successfully. The current trunk states
kept in the DS1 Interface Media Module and switch software are consistent.
If the trunk is busied out, the test will not run but will return PASS. To
verify that the trunk is in-service:
Enter
status trunk
to verify that the trunk is in-service. If the trunk is in-
service, no further action is necessary. If the trunk is out-of-service.
Enter
release trunk
to put the trunk back into in-service.
Retry the test command.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
Check to ensure that the board translations are correct. Use the
list config
command, and resolve any problems that are found.
If the board was found to be correctly inserted in step 1, use the
busyout
board
command.
Use the
reset board
command.
Use the
release busy board
command.
Use the
test board long
command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, check to see that
there is a valid board inserted.
Table 55: TEST #36 Port Audit and Update Test 2 of 2
Error
Code
Test
Result
Description/ Recommendation