Avaya Communication Manager controlled maintenance
AN-LN-PT (Analog Line Port)
84
Maintenance of the Avaya G350 Media Gateway
June 2004
Station Present Test (also called Ringing
Application Test) (#48)
This test applies momentary ringing voltage to the terminal equipment and monitors resulting current
flow to determine whether terminal equipment is connected to the port. This test may cause some
terminal equipment to ring briefly during daily maintenance. If this ringing disturbs the customer or the
terminal equipment, you can disable it via the
Tests
field on the
change station
extension
form.
However, on some software releases, Tests #6, 7, and 35 also are disabled.
5
FAIL
The message waiting lamp update failed. This may be an internal
software error. The translation and ringer updates were not performed
because of this failure.
7
FAIL
The translation update failed. There may be an internal software error.
The ringer update was not performed because of this failure.
8
FAIL
The ringer update failed. There may be an internal software error.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to fail, escalate the problem.
PASS
The software and the port processor have the same status. Investigate
user-reported troubles on this port by running other port tests, by
examining station wiring, or by inspecting the station.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
Check to make sure that the board translations are correct. Use the
list
configuration
command, and resolve any problems.
If the board is correctly inserted, use the busy board GGGVS command.
Use the reset board GGGVS command.
Use the release board GGGVS command.
Use the test board GGGVS long command. This re-establishes the link
between the internal ID and the port.
If this is not the case, check to make sure that a valid board is inserted.
Table 38: TEST #36
Station Status and Translation Audits and Updates 2 of 2
Error
Code
Test
Result
Description/ Recommendation
2 of 2
Summary of Contents for Media Gateway G350
Page 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Page 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Page 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...