Avaya Communication Manager controlled maintenance
AN-LN-PT (Analog Line Port)
Maintenance of the Avaya G350 Media Gateway
79
June 2004
System Technician-Demanded Tests:
Descriptions and Error Codes
CAUTION:
Always investigate tests in the order presented in the table below when inspecting errors
in the system. By clearing error codes associated with the Battery Feed Test, for example,
you may also clear errors generated from other tests in the testing sequence.
.
Table 36: Order of Investigation
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND*
Battery Feed Test (#35)
X
X
ND
Station Present Test (#48)
X
X
ND
Looparound Test (#161)
Note
: This test will abort with Error Code 1412.
X
ND
Conference Test (#7)
Note
: This test will abort with Error Code 1412.
X
ND
NPE Crosstalk Test (#6)
Note
: This test will abort with Error Code 1412.
X
ND
Station Status and Translation Audits and Updates Test
(#36)
X
X
ND
*D = Destructive; ND = Nondestructive