Installing IP500/IP500 V2
Page 91
15-601042 Issue 28c (19 August 2013)
IP Office 9.0
IP500 V2 Installation: Connecting External Expansion Modules
Procedure
1. External expansion modules should not be attached to a control unit that has power.
2. If the IP Office system is being installed in a rack, attach the
rack mounting kit
to the expansion module.
3. Attach the external expansion module's power supply but do not switch power on.
4. Connect the expansion interconnect cable from the module's EXPANSION port to the EXPANSION port on the control
unit. Make careful note of the port used and include this detail on the cable label and any other system records.